Features
1. Adopt FPGA digital control technology, realize intelligent inverter testing process;
2. High performance low (zero) voltage ride through;
3. Voltage and frequency can be set as complex programming such as Step, List stageor Rampvarations, overvoltage/undervoltage, over-frequency/under-frequency test;
4. Harmonic mode, can be superimposed 2 to 40-th harmonics;
5. Three-phase Unbalanced mode, adjustable three-phase voltage and three-phase phase difference, Realize three-phase Unbalanced test;
6. High voltage DC output. Loop test combining PV inverter;
7. Operating in over current shock( up to 3 times of rated current) within 2s,strong load capacity;
8. Complete measurement function: voltage, current, peak current, frequency, active power, apparent power, power factor, voltage crest factor;
9. Online monitoring: IGBT temperature, transformer temperature, fan speed, input voltage and other parameters in output state;
10. Operating data recorder: Automatically record the power status, alarm code etc. in case of alarm, greatly reducing maintenance time;
11. Automatic fan speed adjustment according to the temperature of the power supply, quiet;
12. Lock key, user-friendly design, automatically locking after no-operation for 5 minutes to prevent misuse;
13. 8” color LCD, beautiful appearance;
14. Standard RS232 optional RS485 port, GPIB, Ethernet port or analog control mode;

Order and extensions
1. ANGS series: 0.0 ~ 300.0V/45.00 ~ 65.00Hz, optional 15kVA, 30kVA, 45kVA, 60kVA, 90kVA, 120kVA, 180kVA, 240kVA, 400kVA, 500kVA, 750kVA, 1000kVA.
2. Communication Interface: Standard RS-232 port, optional RS-485, GPIB, Ethernet (Remarks: only can select one of RS-232, RS-485, GPIB, Ethernet)..
3. Remote control: Optional analog control.
    

PC control software

Applications
Grid Simulator Power Supply, the solar cell simulator and power analyzer forming the inverter test system (Solar cell AN51 series solar cell simulator, PV inverter AN87500 multi-channel power analyzer, load ANGS series Grid Simulator Power Supply).

The ANGS series Grid Simulator Power Supply can simulate overvoltage/undervoltage, over-frequency/under-frequency, low (zero) voltage ride through and other curves. The overvoltage/undervoltage, over-frequency/under-frequency, anti-islanding protection of inverter can be tested with anti-islanding load or AC electronic load. AN51 series solar cell simulator can simulate a variety of I-V curves of solar cell to verify the inverter's maximum power tracking capability, and conduct inverter aging test and overvoltage/undervoltage protection; AN87500 multi-channel power analyzer can analyze the inverter’s power, harmonics, efficiency and other parameters, so as to conduct comprehensive analysis of inverter performance. Three kinds of equipment can be integrated using professional PC test software to form a comprehensive inverter test system and solutions.

Grid Simulator Power Supply output high-voltage DC, conducting loop test combing with the inverter (ANGS series Grid Simulator Power Supply, DC output, PV inverter, AC output)

The DC output terminal of ANGS series Grid Simulator Power Supply is connected to the DC input terminal of the inverter. The DC output terminal of the inverter is connected with the output terminal of the Grid Simulator Power Supply in parallel to form a loop test. The energy flows in the loop, saving equipment investment for some specific tests.
 
Specifications of ANGS series

Model ANGS015T ANGS030T ANGS045T ANGS060T ANGS090T ANGS120T ANGS180T ANGS240T
Capacity 15kVA 30kVA 45kVA 60kVA 90kVA 120kVA 180kVA 240kVA
AC input Number of phases Three-phase four-wire + PE
Voltage Phase voltage: 220V ± 33V, line voltage: 380V ± 57V
Frequency 50/60Hz±3Hz
AC output Number of phases Three-phase four-wire
Mode Standard three phase, Unbalanced three phase
Voltage Phase voltage: 0.0 ~ 300.0V
Frequency 45.00~65.00Hz
Rated current 220V 22.7A 45.4A 68.2A 90.9A 136.3A 181.8A 272.7A 363.6A
Setting accuracy Voltage Resolution: 0.1V. Accuracy: 0.2%× reading +0.2%× Full scale
Frequency Resolution: 0.01Hz. Accuracy: 0.05%
Measurement accuracy Voltage Resolution: 0.1V. Accuracy: 0.2%× reading +0.2%× Full scale
Frequency Resolution: 0.01Hz. Accuracy: 0.05%
Current Resolution: 0.1A/1A. Accuracy: 0.3%× display +0.3%× Rated output
Power Resolution: 0.1kW/0.01kW/0.001kW. Accuracy: 0.45%× reading +0.45%× Full scale
Frequency stability ≤0.02%
Voltage distortion Linear load: THD<1%
Transient recovery time 20ms
Three-phase phase difference Standard: 120±2°
Unbalanced: 0.0~359.9°, 0.1° adjustable
Phase voltage crest factor 1.41±0.1
Source voltage effect ≤1%
Load effect ≤1%
Overload capability 105%< output ≤110%: Cut off the output within 15S; 110%< output ≤200%: Cut off the output within 5S
200%< output ≤300%: Cut off the output within 2S; 300%< output: Cut off the output immediately
Impact resistance (1) Withstand 3 times the rated current for 2S; (2) Withstand inductive load with power not more than 0.5 times the rated power or start-up impact of rectifier load with crest factor less than 3.0
Protection IGBT overheating, IGBT overcurrent, transformer overheating, input overvoltage/undervoltage, output overvoltage/undervoltage, output phase failure, output overcurrent, output overload, output short circuit, bus anti-recharge
Efficiency >86%
Function Display 8” LCD, resolution: 800 * 600
Output waveform Sine wave, harmonics (superimposed 2 ~ 40-th harmonics)
Programming Low (zero) voltage through With, minimum response time 20ms
Step Step: 9999
List 100 steps: 999999 cycles
Ramp 100 steps: 999999 cycles
Start ramp time 0.0 ~ 99.9 seconds
Online regulation Output voltage, output frequency in normal mode, online switching of waveform
Memory Power-off memory, store the last output mode and parameters
Shortcuts 10 groups of common modes, 10 groups of harmonics
Line voltage drop compensation 0.000~0.500Ω
Communication ports RS232 (standard), RS485 (optional), GPIB (optional), Ethernet (optional), Flip signal (standard)
Remote control Analog control port (optional)
DC output Voltage DC bus voltage
Current 16A 33A 49A 65A 98A 131A 196A 262A
Working environment Temp. 0~40℃
Humidity 20~90%RH
Dimension W*H*D (mm) 1000×1990×800 1200×1990×800 1200×1990×1000
Weight (KG) 310 360 500 620 810 1060 1280 1380


Model ANGS400T ANGS500T ANGS750T ANGS1000T
Capacity 400kVA 500kVA 750kVA 1000kVA
AC input Number of phases Three-phase four-wire + PE
Voltage Phase voltage: 220V ± 33V, line voltage: 380V ± 57V
Frequency 50/60Hz±3Hz
AC output Number of phases Three-phase four-wire
Mode 三相标准模式、三相不平衡模式   Standard, Unbalanced
Voltage Phase voltage: 0.0 ~ 300.0V
Frequency 45.00~65.00Hz
Rated current 220V 606A 757A 1136A 1515A
Setting accuracy Voltage Resolution: 0.1V. Accuracy: 0.4%× reading +0.4%× Full scale
Frequency Resolution: 0.01Hz. Accuracy: 0.05%
Measurement accuracy Voltage Resolution: 0.1V. Accuracy: 0.4%× reading +0.4%× Full scale
Frequency Resolution: 0.01Hz. Accuracy: 0.05%
Current Resolution: 0.1A/1A. Accuracy: 0.4%× display +0.4%× Rated output
Power Resolution: 0.1kW/0.01kW/0.001kW. Accuracy: 0.7%× reading +0.7%× Full scale
Frequency stability ≤0.02%
Voltage distortion Linear load: THD<3%
Transient recovery time 20ms
Three-phase phase difference Standard: 120±2°
Unbalanced: 0.0~359.9°, 0.1° adjustable
Phase voltage crest factor 1.41±0.1
Source voltage effect ≤2%
Load effect ≤2%
Overload capability 105%< output ≤110%: Cut off the output within 15S; 110%< output ≤200%: Cut off the output within 5S
200%< output ≤300%: Cut off the output within 2S; 300%< output: Cut off the output immediately
Impact resistance (1) Withstand 3 times the rated current for 2S; (2) Withstand inductive load with power not more than 0.5 times the rated power or start-up impact of rectifier load with crest factor less than 3.0
Protection IGBT overheating, IGBT overcurrent, transformer overheating, input overvoltage/undervoltage, output overvoltage/undervoltage, output phase failure, output overcurrent, output overload, output short circuit, bus anti-recharge
Efficiency >86%
Function Display 8” LCD, resolution: 800 * 600
Output waveform Sine wave, harmonics (superimposed 2 ~ 40-th harmonics)
Programming Low (zero) voltage through With, minimum response time 20ms
Step Step: 9999
List 100 steps: 999999 cycles
Ramp 100 steps: 999999 cycles
Start ramp time 0.0 ~ 99.9 seconds
Online regulation Output voltage, output frequency in normal mode, online switching of waveform
Memory Power-off memory, store the last output mode and parameters
Shortcuts 10 groups of common modes, 10 groups of harmonics
Line voltage drop compensation 0.000~0.500Ω
Communication ports RS232 (standard), RS485 (optional), GPIB (optional), Ethernet (optional), Flip signal (standard)
Remote control Analog control port (optional)
DC output Voltage DC bus voltage
Current 436A 545A 818A 1091A
Working environment Temp. 0~40℃
Humidity 20~90%RH
Dimension W*H*D (mm) 3600×2000×1000 4800×2000×1000 6000×2000×1000
Weight (KG) 3050 3380 4870 6360


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message:
 
Products / Products