other
ASA Housing LED Flood light 50W
Motor Stator Comprehensive tester AN96951B(F)

Motor Stator Comprehensive tester AN96951B(F)

  • Details
  • Sales area
  • Enquiry

7 in 1(ACW / DCW / IR / IWT / DCR / L / Q / Phase)

Complete tests programmability

Impulse (IWT) and Hi-pot test with Vacuum

System software with data collection

Software Platform

Program editor

Data collection

Report query

Failure statistical analysis

User management



Ainuo AN9695 test system can be used for not just electrical safety testing, but also quality testing as it provides completed function for motor stator coil inspection.

The Ls/Q (Quality factor) check enable to find some defect coil which may run looks normally, but become hotter than general after it assembled,as a completed motor.

Rotation check is normally to check if the winding connector assembly is correctly performed or not.

AN9695 can provide phase detection with LCR Meter, HallSensor or general rotor rotation test options for this.

It also can provide swappable test fixture to fasten production speed.

Operation system software provides user friendly test program edit interface and tested results display, record and filing management to complete the system to be a best choice for motor stator coil production and quality assurance testing.

Model

AN96951(F)

AN96950(F)

AN9653(F)

ACW

Out voltage range:500~3000VAC,10V/step.(5000V can be modified)

Voltage accuracy:±2.5%×setting+10V Output frequency:50/60Hz

Frequency accuracy:±0.1%×setting

Breakdown current range:0.100~20.00 mA(100Ma can be modified)

Current accuracy:±2.5%×reading+5 counts

IR

Output voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.255uH,0.047uH is optinal

Front time of impulse:0.5uS

Sampling frequency:50kHz~40MHz,15 adjustemnt range

Test time:1~10 times continuous

Ajustment:Area,differ

IW

Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.022uH,0.047uH is optinal

Front time of impulse:0.5us

Sampling frequency:50kHz~40MHz,15 adjustment range

Test time:1~10 times continuous

Ajustemnts:Area,differ

DCR

----

Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω

Accuracy:±0.3%×reading + 3 counts

---

Power/Voltage start

---

Voltage range:

20~300V,10V/step.

Accuracy:±0.3%×reading +0.2%×range

Current range:

0.20~2.00~20.00A

Accuracy:±0.3%×reading + 0.2%×range

Active pwer range:

1.0~99.9W~6KW

Accuracy:±0.8%×reading +0.2%×range

Frequency range:45~500Hz

Accuracy:± 0.1% ×reading

Voltage range:

20~460V,10V/step.

Accuracy:±0.3%×reading +0.2% ×range

Current range:

0.05~6.00~40.00A

(100Ma can be modified)

Accuracy:±0.3%×reading + 0.2% range

Active pwer range:

1.0~99.9W~18kW

Accuracy:±0.8%×reading +0.2×range

Frequency range:45~65Hz

Accuracy:±0.1%×reading

C voltage

---

Voltage range:60.0~600.0V

Accuracy:±0.6%×reading

---

Speed

---

Range:120~99,999rpm

Accuracy:±0.1%×reading+1

---

Rotation

---

RW/RS/RI/KEEP

---

PG single

---

PG power:5V or 12V

Voltage test:0.50~15.0V

Accuracy:±0.5×reading +2 counts

Frequece range:10~1000Hz

Accuracy:±0.1%×reading+1 count

---

Weight(without packaging)

33Kg



 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message:
 
Products / Products