Safety Tester
ASA Housing LED Flood light 50W
6 in 1 Stand Electrical Safety Compliance tester

AN9651S(F)/AN9651F(F)/AN9651B(F),AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  • Details
  • Sales area
  • Enquiry




  Main features

  * Comply with CCC,IEC EN,VED,BS,UL,JIS standard requiements.

  * Latest international standard:500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A

  *6 in 1:AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  Standby power consumption is optional for AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2%

  * Simple operation:LED backlit screen display.menu operation,Chinese/English languages,socket test fixture.

  * Flexible configuration:Built in isolated transformer,AC frequency conversion power supply,frequency conversion power supply and industrial PC combiantion

  * Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.

  Spec.

AC Hipot test  
Booster rated output capacity 500VA(5000V/100mA)  
Booster maximum short-circuit current >200mA  
Output waveform Sine wave, <3%(pure resistance,5000V/1mA),<3%(From empty load to full load)  
 
Output voltage setting Range 500~5000V  
Resolution 5V  
Accuracy ±(3%×setting+10V)  
Frequency setting Range 50Hz/60Hz  
Accuracy ±0.1%×setting  
Alarming limits setting Current upper-limit 0.10~99.99mA  
Current lower-limit 0.00~10.00mA  
Compensation current setting Range 0.00~10.00mA, automatic testing, compensation can be set to ON/OFF  
Time setting Range 1~999s  
Ramp up time range 1~100s  
Accuracy ±(0.1%×setting+1count)  
Breakdown current alarm Range 0.10~99.99mA  
Accuracy ±(3%×reading+3counts)  
Insulation Resistance test  
Rated output capacity 2VA(1000V/2mA)  
Output voltage regulation <3%(From no load to full load)  
Output voltage ripple <1%  
Output voltage setting Range DC 500Vor1000V  
Accuracy ±(3%×setting+3counts)  
Alarming limits setting Resistance upper-limit range 0.0~99.9 MΩ,100~2000MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit)  
Resistance lower-limit range 0.3~99.9 MΩ, 100~2000MΩ  
Time setting Range 1~999s  
Accuracy ±(0.1%×setting+1count)  
Insulation resistance measurement Range 0.0~99.9 MΩ, 100~2000 MΩ  
Accuracy ≤200MΩ: ±(3%×reading+3counts)  
>200MΩ:±(8%×reading+8counts)  
Ground Bond Resistance test  
No load output voltage <12V  
Output current setting Range 3~30A  
Accuracy ±(3%×setting+0.2A)  
Current range instruction Optional: 3 ~ 64A test current  
Current frequency setting Range Sine waveform 50Hz/60Hz  
Accuracy ±0.1%×setting  
Test time setting Range 1~999s  
Accuracy ±(0.1%×setting+1count)  
Result display mode Ground resistance or voltage  
Ground resistance display mode  
Alarming limits setting Resistance upper-limit range 3A≤output current≤10A:10~600 mΩ  
 
 
Resistance lower-limit range 0~100 mΩ  
Compensation resistance setting Range 0~200 mΩ, automatic testing, compensation can be set to ON/OFF  
Ground bond resistance measurement Range 10~600 mΩ  
Accuracy ±(3%×reading+ 5counts)  
Ground voltage display mode  
Alarming limits setting Voltage upper-limit range 30~7500 mV  
Voltage lower-limit range 0~3000 mV  
Compensation voltage setting Range 0~1000 mV, automatic testing, compensation can be set to ON/OFF  
Ground bond resistance measurement Range 10~7500 mV  
Accuracy ±(3%×reading+ 50mV)  
Leakage Current test  
Leakage current test type setting Single phase load, static/dynamic leakage current  
MD network selection Standard IEC 60335-1 figure 4 network;other test network optional  
Alarming limits Setting Current upper-limit range 0.050~9.999mA  
Current lower-limit range 0.000~5.000mA  
Leakage current compensation setting Range 0.000~1.000mA, automatic testing, compensation can be set to ON/OFF  
Time test setting Range 1~999s  
Accuracy ±(0.1%×setting+1count)  
Leakage current measurement Range 0.050~9.999mA  
accuracy DC~10kHz:±(3%×reading+0.010mA)  
 
Output voltage measurement Range 60~280V(phase voltage)  
accuracy ±(0.5%×reading+2counts)  
Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F)  
Alarming limits setting Power upper-limit range 6~6000W  
Power lower-limit range 0~6000W  
Test time setting Range 1~999s  
Accuracy ±(0.1%×setting+1count)  
Voltage measurement Range 60~280V(phase voltage)  
Accuracy ±(0.5%×reading+2counts)  
Current measurement Range 0.030~3.999A, 4.00~25.00A  
Accuracy ±(0.5%×reading+2counts)  
Active power measurement Range 30.0~199.9W:±(0.5%×reading+5W)  
Accuracy 200~6000W(or2000W):±(0.5%×reading+30W)  

More

Model AN9637H(F)/9638H(F) AN9640B(F) AN9651TH(F)
Description
 
4 in 1 Safety Tester
 
AC/DC Hipot, Insulation Resistance, Ground Bond, Wait;
 
Safety accuracy: 2%;
 
AC vector compensation, DC fast discharge, arc detection;
 
Support barcode scanner, U Disk
6 in 1 Safety Tester
 
AC Hipot, Insulation Resistance, Ground Bond, Leakage Current, Power/Start;
 
Safety accuracy: 2%;
 
Classic model, well sold for over 20 years;
7 in 1 Safety Tester
 
AC/DC Hipot, Insulation Resistance, Ground Bond, Leakage Current, Power/Start Start;
 
Safety accuracy: 2%;
 
Built-in 20kVA three-phase isolation transformer;
Picture


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland