Safety Tester
ASA Housing LED Flood light 50W
AC Hipot Tester/Insulation Resistance Tester(AC/IR)

AC Hipot test/Insulation Resistance test/AN9602X(F)/AN9605X(F)/AN9632X(F)/AN9671X(F)

  • Details
  • Sales area
  • Enquiry

Main features

* Latest international standard:Comply with CCC,IEC,EN,VDE,BS,UL,JIS standard requirements.

* Voltage ramp up/down,satisfy latest industrial standard requirements

* Breakdown current upper/lower limit setting,intelligent judgment,sound and light alarm

* AC 50/60HZ output

* Over voltage,over current protection,manual test wires compensation

* VFD display,simple operation

* Remote,RS232/485 interface

* Satisfy low voltage distribution industry latest requirements

Spec.

Model AN9602X(F) AN9605X(F) AN9632X(F) AN9671X(F)

AC Hipot Test

Rated Output 500VA
AC: 5kV/100mA
100VA(AC: 5kV/20mA)  
Output Voltage Set and Range 0.2kV~5.00kV AC,100mA 10V/step 0.2kV~5.00kV AC, 10V/step  
Output Voltage Adjustable Rate ±(2.5% of setting+10V)  
Output Voltage Resolution/Accuracy 10V, ±(2.5% of setting+10V)  
Output Frequency Range 50Hz, 60Hz (Optional)  
Output Waveform Sine waveform, pure resistance, above 200V, distortion <5%  
Upper and Lower Limit Leakage Current Setting AC: Upper: 0.10~100.00mA, Lower:0.10~100.00mA(0=disable), 0.01mA/step AC: Upper: 0.10~20.00mA, Lower:0.10~20.00mA(0=disable), 0.01mA/step  
Breakdown Current Measurement Range 0.100~3.499mA/3.50~100.00mA 0.100~3.499mA/3.50~20.00mA  
Breakdown Current Accuracy ±(2.5% of reading+5 counts)  
Ramp-up Time Setting Range/Resolution 1.0~999.9s (0=disable) 0.1s/step  
Test Time Setting Range/Resolution 1.0~999.9s (LLL=continues) 0.1s/step  
Test wire compensation 0~0.500mA, manual clear offset  

Insulation Resistance Test

Output Voltage Setting and Measurement Range   100V ~1000V DC 5V/step
Output Voltage Resolution/Accuracy   1V , ±(3% of setting+5V)
DC Ripple Coefficient   ≤5% (1kV DC, <1mA, resistance load)
Output Voltage Adjustable Rate   ±(3% of setting+5V)
Test Time Setting Range   1.0~999.9s 0.1s/step (LLL= continues)
Lower limit of Insulation Resistance   1~2000M
Upper limit of Insulation Resistance   1~2000M (0=off)
Insulation Resistance Range   1~2000M, auto shift level
Insulation Resistance Accuracy   500~1000V: ±(3% of reading+8counts) 1~200M;
±(8% of reading+8counts) 200~2000M 
Below 500V: ±(5% of reading+8counts) 1~200M;
±(10% of reading+8counts) 200~2000M
Interface Function RS232(RS485 optional), Remote control(PLC)
Dimension W×H×D(mm) 450×150×440 320×110×400

More

Model AN9637H/9638H AN9640B AN9651TH
Description
 
4 in 1 Safety Tester
 
AC/DC Hipot, Insulation Resistance, Ground Bond, Wait;
 
Safety accuracy: 2%;
 
AC vector compensation, DC fast discharge, arc detection;
 
Support barcode scanner, U Disk
6 in 1 Safety Tester
 
AC Hipot, Insulation Resistance, Ground Bond, Leakage Current, Power/Start;
 
Safety accuracy: 2%;
 
Classic model, well sold for over 20 years;
7 in 1 Safety Tester
 
AC/DC Hipot, Insulation Resistance, Ground Bond, Leakage Current, Power/Start Start;
 
Safety accuracy: 2%;
 
Built-in 20kVA three-phase isolation transformer;
Picture


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message: