Safety Tester
ASA Housing LED Flood light 50W
Electrical Safety Comprehensive analyzer

Electrical Safety Comprehensive analyzer AN9642H(F)/AN9639H(F)

  • Details
  • Sales area
  • Enquiry

* Integration:ACW,DCW,IR,GB,LC,PWR,STR(7 functions in 1)

* Information:barcode recognition,program contorl,data storage,query statistics

* High quality:stable,accurate data,fast test,easy operation

* Strong Expansion:Support ESRS software,IN-PAD termianl and power supply

Main features

* 7 in 1:AC withstand voltage 5000V/40mA,DC withstand voltage 6000V/10mA,insulation resistance 2500V/9999MΩ,ground resistance 32A/600mΩ,leakage current complying with IEC60990 and Figure 4 in GB/T12113,AN9642H also has operating power 300V/20A and low voltage start functions.

* Fast test: if the setting time is total 5s,it can be fastert finshed in 5.6s for all testes, The accuracy of safety test is 2%,power parameters accuracy is 0.2% and the minimum measurement power is 1w.

* Automated test: Automation and information interface,Supporting combinging with barcode scanners,servers and other automated testers to realize testing automatically.

* Intelligent management:Barcode recognition,matching tes program,intelligent programmable control of the test conditions;test data storage(local U disk), server data exchange (network interface orRS232), data analysis (ESRS software) and other information management;meeting the MES management requirements in modern line.

* Open extension:Rich extension,including 100mA with stand voltage,64A ground,the measurement network selection of leakage current and other options,optional IN-PAD,software(ESRS),barcode scanners,power supply etc.

AC Withstand Voltage Test

Rated output

200VA (5000V/40mA), short circuit current is greater than 200mA;

[Optional: 5000V/100mA]

Output voltage

Range/accuracy

100~5000V, ± (2%× setting + 5 words)

Output frequency

Range/accuracy

50Hz or 60Hz, ±0.1%× setting

Alarm current

Upper limit/accuracy

0.10~ or 40.00mA, ± (2%× setting + 5 words)

Lower limit /accuracy

0.000~9.999mA, ± (2%× setting + 5 words)

Time

Range

0.5~999.9s (0: infinite time)

Ramp time

0.1~999.9s

Descent time

0.1~999.9s

Accuracy

± (0.2%× setting + 1 word)

Measure meter

Voltage range/accuracy

0.01~5.00kV, ± (1.5%× reading + 1 word)

Frequency range/accuracy

50Hz or 60Hz, ±0.1%× reading

Current range/accuracy

0.10~40.00mA, ± (2%× reading + 2 words)

Time range/accuracy

0.1~999.9s, ± (0.2%× reading + 1 word)

Output voltage wave, distortion, adjusting rate

Sine wave, less than 2% (pure resistive load), less than (2% × setting + 5V) (from zero to full load)

Start voltage

(0%~50%)× output voltage setting

Current compensation

0.000~40.00mA, Auto/manual

Arc detection

Level 1~9, 9: highest level; 0: off

DC withstand voltage test

Output voltage

Range/accuracy

100~6000Vdc, ± (2%× setting + 5 words)

Alarm current

Upper limit/accuracy

0~10000μA, ± (2%× setting + 5 words)

Lower limit /accuracy

0.0~999.9μA, ± (2%× setting + 5 words)

Time

Range

0.5~999.9s (0: infinite time)

Ramp time

0.1~999.9s

Descent time

0.3~999.9s (0, off)

Accuracy

± (0.2%× setting + 1 word)

Measure meter

Voltage range/accuracy

0.01~6.00Vdc, ± (1.5%× reading + 1 word)

Current range/accuracy

0.0~10000uA, ± (2%× reading + 5 words)

Time range/accuracy

0.1~999.9s, ± (0.2%× reading + 1 word)

Rated output

60VA (6000Vdc/10mA)

Output voltage fluctuation, regulation

Less than 5% (purely resistive load, 6000V/10mA), less than (2% × setting + 5V) (from zero to full load)

Compensation current

0 ~200.0μA, Auto/manual

Start voltage

(0%~50%)×output voltage setting

Charging current lower limit

(0~3.500) μA, Auto/manual

Discharge time

≤200ms

Arc detection

Level 1~9, 9: highest level; 0: off

Insulation resistance test

Output voltage

Range/accuracy

100~2500Vdc, ± (2%× setting +5V)

Alarm resistance

Upper/lower limit

1~9999MΩ

Accuracy

100-499V, 1~1000MΩ, ± (8%× setting + 2 words)

1000~2000MΩ, ± (12%× setting + 2 words)

500-2500V, 1~199MΩ, ± (2%× setting + 2 words),

200~999MΩ, ± (5%× setting + 2 words)

1000~9999MΩ, ± (15%× setting + 2 words)

Time

Ramp time

0.1~999.9s

Delay decision time

0, 0.5~999.9s (0: infinite time)

Range

0, 0.5~999.9s (0: infinite time)

Descent time

0.1~999.9s

Accuracy

± (0.2%× setting + 1 word)

Measure meter

Voltage range/accuracy

100~2500Vdc, ± (2%× reading + 5 words)

Resistance range/accuracy

1~9999MΩ;

100-499V, 1~1000MΩ, ± (8%× reading + 2 words)

1000~2000MΩ, ± (12%× reading + 2 words)

500-2500V, 1~199MΩ, ± (2%× reading + 2 words),

200~999MΩ, ± (5%× reading + 2 words)

1000~9999MΩ, ± (15%× reading + 2 words)

Time range/accuracy

0.1~999.9s, ± (0.2%× reading + 1 word)

Charging current lower limit

0~3.500μA, Auto/manual

Grounding resistance test

Rated output

Maximum output current: 32A; maximum test resistance: 600mΩ; maximum open circuit voltage: 12V;

[Optional: 64A ground test current]

Output current

Range/accuracy

2.0~32.0A, ± (2%× setting + 5 words)

Output voltage

Range/accuracy

3.0~10.0V, ± (2%× setting + 5 words)

Output frequency

Range/accuracy

Sine wave, 50Hz or 60Hz, ±0.1%× setting

Alarm limit

Resistance upper/lower limit

2.0~10.6A: 0.1~600mΩ;

10.7~32.0A: 0.1~R mΩ, R= (6400/current setting) mΩ. As the current range is switched, the tester will automatically calculate the maximum range.

Error

± (2%× setting + 5 words)

Compensation resistance

Range

0~100 mΩ, automatic measurement , compensation On/Off

Test time

Range/accuracy

0.5~999.9s (0: infinite time); ± (0.2%× setting + 1 word)

 

 

 

 

 

Measure meter

Current range/accuracy

2.0~32.0A ( or 64A), ± (2%× reading + 2 words)

Voltage range/accuracy

3.0~10.0V , ± (2%× reading + 5 words)

Resistance range/accuracy

10.0~99.9~100~600mΩ; ± (2%× reading + 5 words)

Current Precision

 

Resistance

Time range/accuracy

0.1~999.9s; ± (0.2%× setting + 1 word)

Leakage current test

Type

Single-phase load (300V/20A), dynamic leakage current test under the operating temperature and static leakage current test under the non-operating temperature

Leak test body network (MD card)

Standard network, GB/T 12113 Fig. 4; [Optional: other leak test network]

Alarm leakage current

Upper limit

0.050~9.999mA

Lower limit

0.000~5.000mA

Leakage current compensation

Range

0.000~1.000mA, automatic measurement , compensation On/Off

Test time

Range/accuracy

0.5~999.9s (0: infinite time), ± (0.2%× setting + 1 word)

Leakage current measurement

Range

0.050~9.999mA

Accuracy

DC~10kHz: ± (3%× reading +0.010mA)

10k~1MHz: ± (5%× reading +0.050mA)

Output voltage measurement

Range/accuracy

60~280V (phase voltage), ± (0.5%× reading + 2 words)

Start Performance Test (AN9642H only)

Alarm current

Upper limit

0.020~25.00A

Lower limit

0.000~25.00A

Current measurement

Range/accuracy

0.020~25.00A, ± (0.1%× display +0.1%× range)

Voltage

Range/accuracy

5.00~300.0V (phase voltage), ± (0.1%× display +0.1%× range)

Test time

Range/accuracy

0.5~999.9s (0: infinite time), ± (0.2%× setting + 1 word)

Interfaces of rear panel

Remote controller

Standard, standard foot switch (start)

Warning light

Standard, standard three-color warning lights (Test/Pass/Warning)

Communication

Standard RS232, Optional RS485, Ethernet ports, GPIB etc

I/O

Optional Start/Stop/Test/Pass/Alarm.

Printer

Optional, Dot Matrix/Mini printer.

General Specification

Verification & Calibration

23±5, (45~75) %RH , less dust

Ambient

0 ºC ~40ºC, , (5~90) %RH , less dust

Storage

-10~55, (5~95) %RH , less dust

Power supply

220V±10%, 50Hz±5%

Power consumption

Maximum 300VA (excluding operating power of objects under test)

Weight

Approx. 30kg

Dimensions (mm)

426 (W)x 550 (D)x 242 (H), foot height (10+10)mm



 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message:
 
Products / Products