Safety Tester
ASA Housing LED Flood light 50W
Multiple function Electrical Safety analyzer

AN9638H(F)/AN9637H(F),AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  • Details
  • Sales area
  • Enquiry

  THE SAFETY TESTER IS THE GENERIC TERM TO COVER THE 3 OR 4 TESTS OF THE ELECTRICAL SAFETY STANDARDS, FROM THE INTERNATIONAL STANDARDS

  ground bond test (also called bonding test, ground continuity test )

  - insulation test (also called high resistance test, megger test)

  - hipot test to make a high voltage test (also called dielectric strength test, hipot test, hi-pot test, breakdown test or flash test)

  - leakage current measurement (also called line leakage test)

  The final purpose of those tests is to validate that the product under test is safe for the end user, and complies with the quality requirements from the Low Voltage Directive (LVD), applicable to the corresponding standards (IEC335, IEC950, IEC601, IEC1010, IEC598, IEC990, IEC204...)

  APPLICATION

  MANUFACTURER, LABORATORY, HIGH SPEED PRODUCTION, MAINTENANCE, IN ORDER TO COMPLY WITH THE LOW VOLTAGE DIRECTIVE

  

  • IEC 335 household manufacturer (washing machines, coffee machines, fridges, heaters, boilers, …)

  • IEC 204 industrial equipment (compressor, electrical tools, …)

  • IEC 598 lighting industry (street lights, professional lighting, medical lighting, bulbs, …)

  • IEC 601 medical industry (scanners, surgery equipments, X-ray, electrical beds, …)

  • IEC 950 information technology industry (modems, satellite receivers, servers, printers,cash dispensers, …)

  • IEC 1010 measurement, control and laboratories industry (electrical meters, test & measurement equipment, …)

  SPECIFICATION OVERVIEW

  FROM LABORATORY TO PRODUCTION TESTING, OUR RANGE COVERS THE FOLLOWING SPECIFICATIONS

  • ground bond test up to 64A AC with resistance measurement up to 600mΩ

  • insulation test with DC Voltage from 1V up to 1000 VDC (1V steps),500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A

  • leakage current measurement in single or three phases, according to all current international standards

  • AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  • power measurement and cos φ measurement

  • Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.

  • GPIB, RS232, Ethernet, 0-10V, PLC available

  • ESRS software for quality purposes, traceability and professional reporting

AC Hipot test

Rated output capacity

AN9638H(F)

500VA5000V/100mA),short circuit current >200mA

AN9637H(F)

200VA5000V/40mA),short circuit current >200mA

Output voltage setting

RangeAccuracy

1005000V±2%×setting+5counts

Output frequency setting

RangeAccuracy

50Hz or 60Hz±0.1%×setting

Alarm current limits setting

Upper-limit rangeAccuracy

0.10100.00mAor 40.00mA),±2%×setting+5counts

Lower-limit rangeAccuracy

0.0009.999mA±2%×setting+5counts

Time setting

Range

0.5999.9s0 is infinite

Ramp up/down time range

0.1999.9s

Accuracy

±0.2%×setting+1count

Measurement

Voltage rangeAccuracy

0.015.00kV±1.5%×reading+1count

Frequency rangeAccuracy

50Hz or 60Hz±0.1%×reading

Current rangeAccuracy

0.10100.00mAor 40.00mA),±2%×reading+2counts

Time rangeAccuracy

0.1999.9s±0.2%×reading+1count

Output voltage waveform, distortion, regulation

Sine wave<2%pure resistance load),<2%×setting+5V)(from empty load to full load

Start voltage setting

0%50%×output voltage setting

Current compensation setting

0.000~100.00mAor 40.00mA),automanual

Arc detection

19 level9 level is optimally sensitive0 is OFF

DC Hipot test

Output voltage setting

RangeAccuracy

1006000VDC±2%×setting+5counts

Alarm current limits setting

Upper-limitAccuracy

0~10000μA±2%×setting+5counts

lower-limitAccuracy

0.0~999.9μA±2%×setting+5counts

Time setting

Range

0.5999.9s0 is infinite

Ramp up time range

0.1999.9s

Ramp down time range

0.3999.9s0 is OFF

Accuracy

±0.2%×setting+1 count

Measurement

Voltage rangeAccuracy

0.016.00VDC±1.5%×reading+1count

Frequency rangeAccuracy

0.010000uA±2%×reading+5count

Current rangeAccuracy

0.1999.9s±0.2%×reading+1count

Rated output capacity

60VA6000VDC/10mA

Output voltage ripple, regulation

<5%pure resistance load6000V/10mA),<2%×setting+5V)(from empty load to full load

Compensation current Setting

0 ~200.0μAauto, manual

Start voltage setting

0%50%× setting output voltage

<span style="font-size: 9px;" color:#313131;"="">Charging current lower limit

0~3.500μAauto, manual

Discharge time

≤200ms

Arc detection

19 level9 level is optimally sensitive0 is OFF

Insulation Resistance test

Output voltage setting

RangeAccuracy

1002500Vdc±2%×setting+5counts

Alarm resistance setting

Range

19999MΩ

Accuracy

100-499V1~1000MΩ,±(8%×setting+2counts)

1000~2000MΩ,±(12%×setting+2counts)

500-2500V1~199MΩ,±(2%×setting+2counts)

200~999MΩ, ± (5%×setting+2counts)

1000~9999MΩ, ± (15%×setting+2counts)

Time setting

Ramp up time range

0.1999.9s

Adjustment delay time

00.5999.9s0 is infinite

Test time range

00.5999.9s0 is infinite

Ramp down time range

0.1999.9s

Accuracy

±0.1%×setting+0.1s

Measurement

Voltage range, accuracy

1002500Vdc±2%×reading+5counts

Resistance range, accuracy

19999MΩ

100-499V1~1000MΩ,±(8%×reading+2counts)

1000~2000MΩ,±(12%×reading+2counts)

500-2500V1~199MΩ,±(2%×reading+2counts)

200~999MΩ, ± (5%×reading+2counts)

1000~9999MΩ, ± (15%×reading+2counts)

Time rangeaccuracy

0.1999.9s±0.2%×reading+1counts

Charging current lower limit

0~3.500μAauto, manual

Discharge time

≤200ms

Ground Bond test

Rated output

AN9638H(F)

Max output current is 64Amax testing resistance 600mΩopen-circuit voltage <12V

AN9637H(F)

Max output current is 32Amax testing resistance 600mΩopen-circuit voltage <12V

Output current setting

RangeAccuracy

2.032.0Aor 64A),±2%×setting+5counts

Output voltage setting

RangeAccuracy

3.0~10.0V ±(2%×setting+5counts)

Output frequency setting

RangeAccuracy

Sine wave50Hz or 60Hz±0.1%×setting

Alarm limits setting

Resistance upper/lower limits

2.0~10.6A0.1~600mΩ

10.7~32.0Aor 64A):0.1~R mΩamong R=6400 / set current valuewhen current range changsTester for automatic calculation range scope biggest

Tolerance

±(2%×setting+5counts)

Compensation resistance setting

Range

0100 mΩautomatic measurementON/OFF

Test time setting

RangeAccuracy

0.5999.9s0 stand for time infinite length);±0.2%×setting+1count

 

 

 

 

 

Measurement

Current rangeaccuracy

2.032.0Aor 64A),±2%×reading+2counts

Voltage range,accuracy

3.0~10.0V ±(2%×reading+5counts)

Resistance range, accuracy

10.0~99.9~100~600mΩ±(2%×reading+5counts)

 

64A current calculated method is same

Time rangeaccuracy

0.5999.9s0 stand for time infinite);±0.2%×setting+1count

Extended function

Communication function

Address setting

0999

Baud rate setting

3001200240048009600192000

Verification mode setting

Noneoddeven

Bar code scanning

Bar code scanning function

ON/OFF

Bar code length setting

130

Model identification number

Start bit select 130max length 16 Bit

Function allocation explain

Hardware interface is optional

print function

printer type setting stylus printer miniprinter


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message:
 
Products / Products