DC Power Supply AN50 series

DC Power Supply AN50 series

    AN504XX(F): 35V output,6kW/9kW/15kW/30kW   AN505XX(F): 60V/80V output,6kW/9kW/15kW/30kW   AN506XX(F): 120V/150V output,6kW/9kW/15kW/30kW   AN507XX(F): 330V output,6kW/9kW/15kW/30kW   AN508XX(F): 630V output,15kW/30kW

  The AN50 series DC power supply adopts high-frequency PWM control and phase-shifted full-bridge conversion, fast dynamic response, strong overcurrent capability, low output ripple, featuring compact, light, quiet, high efficiency, simple operation and cost-effective. It can be used for manufacturing, testing and maintenance of military electronic equipment such as motors, power tools, automotive electronics, switching coils and DC switches, aircraft and airborne equipment, radar, navigation, etc., as well as industrial and mining enterprises, colleges and universities laboratories, research institute, etc.

  Features

  1.Work mode: CV, CC;

  2.Use high frequency PWM and full-bridge convert technique to achieve high efficiency;

  3.High power density design, standard case, wide application;

  4.LCD display, convenient for operation;

  5.10 setting and quick recall groups;

  6.Exceptional output stability. Source voltage effect<0.2%, Load effect<0.3%, Temperature drifts <0.4%, time varying drifts <0.3%;

  7.Output voltage drop compensation, ensure the voltage accuracy under big current;

  8.Providing RS232(standard) ,GPIB(optional), suitable for remote control;

  9.Protect function: output short circuit, output over current, output limit current, over heat, input under voltage, input phase lack protection, sense terminal over compensation protection, sense terminal reverse connection protection.

  10.Sequence test: 5 groups, 10 steps per group, 3000 cycles.

  11.Analog interface (optional): start, stop, alarm, 0-5V/0-10V or 4-20mA analog control output.

  Order and extensions

  AN504XX(F): 35V output,6kW/9kW/15kW/30kW

  AN505XX(F): 60V/80V output,6kW/9kW/15kW/30kW

  AN506XX(F): 120V/150V output,6kW/9kW/15kW/30kW

  AN507XX(F): 330V output,6kW/9kW/15kW/30kW

  AN508XX(F): 630V output,15kW/30kW

  Specifications of AN50 series

Model AN50402S(F)
AN50402T(F)
AN50403S(F)
AN50403T(F)
AN50405(F) AN50410(F)  
Input Single phase:220V±22V,50/60±5Hz
(3-phase 3-wire: 380V±40V,50/60±5Hz)
3-phase 3-wire: 380V±40V,50/60±5Hz  
Output Voltage  0V-35V  
Current  0-200A  0-300A  0-500A  0-1000A  
Power  0-6kW  0-9kW  0-15kW  0-30kW  
Display Mode  LCD display,4digits  
Testing Accuracy Voltage ≤±0.5%(full scale value) (15V-35V):≤±1%(Reading);(0-15V):≤±1%(Reading)±1V    
Current ≤±0.5%(full scale value) ≤±1%(Reading +range)  
Ripple and Noise 20Hz-20MHz Vrms  120mV  160mV  
Vpp  500mV  800mV  
Effect Source voltage effect±0.1%;Load effect:±0.2%  
Over load 105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;Rated current>200%,the output will be stopped immediately;  
Protection  Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection  
Transient response time Meet the requirements of GJB572A Figure 13≤10ms  
Max output voltage drop compensation  4V  
Communication  RS232(Standard)/RS485(Optional)  
Memory  10 groups of memory storage, power down memory function  
List test function 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)  
Analog interface(optional) Start、stop、alarm、0-5V/ 0-10V or 4-20mA analog control output None  
Environment Temperature:0~40℃;Humidity:20~90%RH  
Dimension W×H×D(mm)   480×225×620  440×600×660 540×1230×670  
Weight  55kg  90kg 180kg  
Model  AN50502S(F)
  AN50502T(F)
 AN50503S(F)
AN50503T(F)
AN50505(F) AN50510(F)
Input Single phase:220V±22V,50/60±5Hz
(3-phase 3-wire: 380V±40V,50/60±5Hz)
3-phase 3-wire: 380V±40V,50/60±5Hz
Output Voltage  0V-60V
Current  0-100A  0-150A  0-250A  0-500A
Power  0-6kW  0-9kW  0-15kW  0-30kW
Display Mode  LCD display,4 digits
Testing Accuracy Voltage ≤±0.5%(full scale value) (15V-60V):≤±1%(reading value);(0-15V):≤±1%(reading value)±1V  
Current ≤±0.5%(full scale value) ≤±1%(reading value + range)
Ripple and Noise 20Hz-20MHz Vrms 180mV 280mV
Vpp 750mV 1200mV
Effect Source voltage effect:±0.2%;Load effect:±0.2%
Over load 105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;
Rated current>200%,the output will be stopped immediately;
Protection Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time Meet the requirements of GJB572A Figure 13≤10ms
Max output voltage drop compensation  4V
Communication  RS232(Standard)/RS485(Optional)
Memory 10 groups of memory storage, power down memory function
List test function  5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional) Start、stop、alarm、0-5V/ 0-10V or 4-20mA analog control output None
Environment  Temperature :0℃-40℃,Humidity :20~90%RH
Dimension W×H×D(mm)  480×225×620  440×600×660 540×1230×670
Weight  55kg  90kg  180kg

Model AN50602S(F) 
(AN50602T(F))
AN50603S(F) 
(AN50603T(F))
AN50605(F)  AN50610(F)
Input Single phase:220V±22V,50/60±5Hz
(3-phase 3-wire:380V±40V,50/60±5Hz)
3-phase 3-wire:380V±40V,50/60±5Hz
Output Voltage  0V-120V
Current  0-50A  0-75A  0-125A  0-250A
Power  0-6kW  0-9kW  0-15kW  0-30kW
Display Mode  LCD display,4 digits
Testing Accuracy Voltage ≤±0.5% (40V-120V):≤±1%(Reading);(1V-40V):≤±1%(Reading)±1V  
Current ≤±0.5% ≤±1%(Reading+Range)
Ripple and Noise 20Hz-20MHz Vrms  200mV  350mV
Vpp  800mV  1200mV
Effect Source voltage effect:±0.2%;Load effect:±0.2%
Over load 105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;
Rated current>200%,the output will be stopped immediately;
100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection  Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time  Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation  4V
Communication  RS232(Standard)/RS485(Optional)
Memory 10 groups of memory storage, power down memory function
List test function  5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional) Start、stop、alarm、0-5V/ 0-10V or 4-20mA analog control output
Environment  Temperature :0℃-40℃,Humidity :20~90%RH
Dimension W×H×D(mm)   480×225×620  440×600×660 550×1200×660
Weight  55kg  90kg  240kg

Model  AN50702S(F)   AN50703S(F)  AN50705(F)  AN50710(F)
Input Single phase:220V±22V,50/60±5Hz 3-phase 3-wire:380V±40V,50/60±5Hz
Output Voltage  0V-330V
Current  0-20A  0-30A  0-50A  0-100A
Power  0-6kW  0-9kW  0-15kW  0-30kW
Display mode  LCD display,4 digits
Testing Accuracy Voltage (100V-330V):≤±1(Reading)%;(3V-100V):≤±1%(Reading)±1V  
Current ≤±1%(Reading+Range)
Ripple and Noise 20Hz-20MHz Vrms  300mV  350mV
Vpp  900mV  900mV
Effect Source voltage effect:±0.2%;Load effect:±0.2%
Over load 105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection  Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time  Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation 15V
Communication RS232(Standard)/RS485(Optional)
Memory 10 groups of memory storage, power down memory function
List test function  5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional) Start、stop、alarm、0-5V/ 0-10V or 4-20mA analog control output
Environment Temperature:0~40℃;Humidity :20~90%RH
Dimension W×H×D(mm) 441×177.8×550 550×1200×660
Weight 50kg  240kg

Model  AN50805(F) AN50810(F)
Input  3-phase 3-wire:380V±40V,50/60±5Hz
Output Voltage  0-630V
Current  0-25A  0-50A
Power  0-15kW  0-30kW
 Display mode  LCD display,4 digits
 Testing Accuracy Voltage (100V-630V):≤±1%(Reading);(6V-100V):≤±1%(Reading)±1V 
Current  ≤±1%(Reading+Range)
 Ripple and Noise 20Hz-20MHz Vrms  350mV
Vpp  900mV
Effect  Source voltage effect:±0.2%;Load effect:±0.2%
Over load 100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection  Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time  Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation  15V
Communication  RS232(Standard)/RS485(Optional)
Memory 10 groups of memory storage, power down memory function
List test function(Optional) 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times
Analog interface(optional) Start、stop、alarm、0-5V/ 0-10V or 4-20mA analog control output
Environment Temperature:0~40℃;Humidity:20~90%RH
Dimension W×H×D(mm)  550×1200×660
Weight  240kg
 