Intelligent Electrical Safety Comprehensive AnalyzerAN1640H(

Intelligent Electrical Safety Comprehensive AnalyzerAN1640H(

    AN1640H(F)/AN1651H(F)

  AN16 series safety analyzer is mainly used to provide the test solutions for electric car, grid, photovoltaic, electrical appliances, information equipment, medical equipment industry as well as innovative solutions for the various electrical measurement.

  Features

  Unparalleled accuracy

  With continuous improvement and improvement, the AN16 series safety analyzer is a highly tested and highly reliable safety instrument designed and developed by Ainuo company. The main safety accuracy index is up to 1%, and the precision of built-in electrical parameter analysis module is up to 0.2%.

  AN16 series safety analyzer passes a variety of harsh experimental certification, it can meet your test requirements in the cold, hot and/or high humidity environment.

  AN16 series of safety analyzer has unique automatic calibration function, it can make automatic calibration for whole machine with AN16 series, and thus relieve your worries.

  High Speed

  AN16 series safety analyzer supports ground and withstand voltage / insulation parallel test, dual-station asynchronous serial test, dual-station intelligent parallel test. The test speed is increased several times.

  The original fast communication response mechanism, all communication commands within 0.1s to complete the data then returned, it is easy to automate transformation.

  Innovative hardware control and software algorithms, Single safety test as fast as 0.5s to complete.

  Intelligent management

  AN16 series of safety analyzer has unique intelligent features, in-built the first industry-based Android development platform, it will more and more understand you!

  Support intelligent input reminder: Automatically record your common settings parameters, and realize intelligent quick input;

  Support wifi networking, LAN networking, remote control, data acquisition;

  Support RFID, barcode scanning interface, and achieve rapid selection of groups, data storage;

  Support Ainuo new customized PLC interface function;

  Built-in DC fast discharge module, open detection module, ARC test module, to solve the safety problems;

  Leakage current test in compliance with IEC60335-1-2010, support peak mode, RMS mode test., AC/DC component measurement mode.

  Informatization

  Android system platform: The safety analyzer is developed and operated based on the original software platform of Android system. The touch operation conforms to modern operation habits, and makes the editing of test items easier and faster. By identifying the barcode and electronic label, the program is matched automatically, and the test starts automatically, synchronous storage of product identity data and test data.

  Mass data storage: Built-in large-capacity storage space, supports external U-disk, providing data support for data analysis and quality control.

  Server access port: support current mainstream SQL, ORACLE server database access, no need for external computer system, easy to access MES system, and achieving test data upload and test program download.

  Original UI

  The AN16 series safety analyzers feature excellent functions and performance, bringing you new experience in human-machine interaction (HMI).

  Original design, professional UI platform for safety testing, beautiful screen, touch screen, and one-touch operation.

  Applications

MD network selection Standard
MD-A network GB/T12113-2003/IEC60990-1999 Measurement of contact current
GB4706.1-2005/IEC60335-1-2004 Household and similar electrical appliances
IEC60335-1-2010 Household and similar electrical appliances (latest IEC)
GB7000.1-2015/IEC60598-1-2014 Lamps
GB4943.1-2011/IEC60950-1-2005 Information technology equipment
GB 7260.1-2008/IEC62040-1-1:2002 UPS(Main reference GB4943.1)
GB4793.1-2007/IEC61010-1-2001 Electrical equipment for measurement, control and laboratory use
GB8898.1-2011/IEC60065-1-2005  Audio, video and similar electronic equipment
GB/T 19212.1-2016/IEC61558-1:2009 Transformers, reactors, power supply and their combinations
GB/T 18487.1-2015 Electric vehicle conductive charging system
MD-B Network UL1563-2006 SPA electrical equipment
MD-C Network GB9706.1-2020/IEC60601-1-2012 Medical electrical equipment
UL2601-2002 Medical electrical equipment
MD-D Network UL544-1998 Dental medical equipment
MD-E Network UL544NP-1998 Dental medical equipment
UL471-1996 Commercial refrigerators and freezers
UL923-2002 Household or commercial microwave oven
UL484-2014 Room air conditioner
UL1029-2007 High intensity gas-discharge lamp
UL867-2004 Air cleaner
UL697-2012 Deformation toys
MD-F Network GB/T12113-2003/IEC60990-1999 Measurement of contact current
GB7000.1-2015/IEC60598-1-2014 Lamps
MD-G Network GB4943.1-2011/IEC60950-1-2005 Information technology equipment
GB 7260.1-2008/IEC62040-1-1:2002 UPS(Main reference GB4943.1)
GB4793.1-2007/IEC61010-1-2001 Electrical equipment for measurement, control and laboratory use
MD-H Network GB7000.1-2015/IEC60598-1-2014 Lamps
UL1310 CLASS 2 Power supply



  Specification of AN1640H(F)/AN1651H(F)
 

Features Technical indicator
AC withstand voltage test Rated output capacity 200VA(5000V/40mA)optional:500VA;
Output voltage setting Range/Accuracy  Range:(100~5000)V,
Resolution: 1V,
±(1% × setting + 5V)
Output frequency setting Range/Accuracy  50Hz/60 Hz,
±0.1 Hz
Alarm current setting Upper limit range /Accuracy Range:(0.00~100.00)mA,
Resolution: 0.01mA,
±(1% × setting + 5 counts)
Lower limit range/Accuracy Range:(0.00~9.999)mA, Resolution: 0.001mA,
±(1% × setting + 5 counts)
Time setting Range of test time/ Accuracy Range: 0,(0.5~999.9)s,0  is infinite,
Resolution is 0.1s,
±(0.1% × setting + 2 count )
Range of ramp-up  time/ Accuracy Range: 0,(0.1~999.9)s,0  is off, Resolution is 0.1s,
±(0.1% × setting +2 count)
Range of ramp-down  time/ Accuracy Range:0,(0.1~999.9)s, 0 is off,resolution is 0.1s,
±(0.1% × setting + 2 count)
Arc detection 1~9 (9 corresponds to most sensitive), 0 means the arc function is Off.
DC withstand voltage test Rated output 60VA(6000VDC/10mA)
Output voltage setting Range/Accuracy Range:(100-6000)VDC, Resolution: 1V;
±(1% × setting + 5V)
Alarming current setting Upper limit range/Accuracy Range:(0.0~10000)μA, Resolution: 0.1μA/1μA,
±(1% × setting + 5 counts)
Lower limit range/Accuracy Range:(0.0~999.9)μA,
Resolution: 0.1μA,
±(1% × setting + 5 counts)
Time setting Range of test time/ Accuracy Range: 0, (0.5~999.9)s, 0 is infinite, Resolution: 0.1s,
±(0.1% × setting + 2 count)
Range of ramp-up time/ Accuracy Range: 0,(0.4~999.9)s, 0 is off,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
Range of ramp-down  time/ Accuracy Range: 0,(1.0~999.9)s, 0 is off,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
Arc detection 1~9(9 corresponds to most sensitive), 0 means that arc function is Off.
Insulation resistance test Rated output 2500VDC/50GΩ
Output voltage Range/Accuracy Range:(100-2500)VDC,
Resolution: 1V,
Accuracy: ±(1% × setting + 5V)
Alarm resistance setting Range of upper/lower limits Range: 0.1MΩ-50000MΩ,
upper limit includes no upper limit setting
Accuracy 100-499V: 0.10MΩ-999.99MΩ, 1000-2000MΩ, ±(5% × setting + 2 counts)
500-2500V:
0.10-999.99MΩ, ±(2% × setting + 2 counts)
1000-9999MΩ, ±(5% × setting + 2 counts)
10000-50000MΩ, ±(15% × setting + 2 counts)
Time setting Range of ramp-up  time/ Accuracy Range: 0,(0.1-999.9)s, 0 is infinite,,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
Range of delay time/ Accuracy Range: 0,(0.5-999.9)s, 0 is off,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
Range of ramp-down  time/ Accuracy Range: 0,(1.0~999.9)s, 0 is off,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
Grounding resistance test Rated output Max test current 32A, max resistance 600mΩ, open-circuit voltage <12V
Output current setting Range/ Accuracy Range:(2.0A-32.0A)AC,
Resolution: 0.1V,
±(1% × setting + 2 counts)
Output voltage setting Range/ Accuracy Range:(3.0-10.0)VAC,
Resolution: 0.1A,
±(1% × setting + 2 counts), in the open circuit case
Output frequency setting Range/ Accuracy 50Hz/60Hz, accuracy: ±0.1Hz
Alarm limit setting Range of resistance upper/lower limit 3 A≤ output current ≤10A: 10~600 mΩ
11A≤ output current ≤25A: 10~300 mΩ
26A≤ output current ≤32A: 10~200 mΩ
Resolution:0.1/1mΩ
Accuracy <100 mΩ, ±(1% × setting + 1 mΩ);
≥100 mΩ, ±(1% × setting + 2 counts)
Test time setting Range/ Accuracy Range: 0,(0.5~999.9)s, 0 is infinite, resolution: 0.1s,
±(0.1% × setting + 2 count)
Leakage current test Test method Single-phase load, leakage current at operating temperature (dynamic) and leakage current at non-operating temperature (static), G-L, G-N, AUTO (G-L, G-N); external isolation transformer or variable frequency power supply is required to provide the required voltage and frequency.
State of operating power supply Polarity: on, off, automatic; neutral: on, off; ground: on, off
Built-in 8 human networks
(Standard A/F/H networks, other network optional, choose C/D/E network for testing of medical device)
 
 
Test voltage output Single-phase, external isolation transformer or variable frequency power supply is required to provide the voltage and frequency required for testing.
Load current Upper limit: 40A
Contact current/leakage current upper/lower limit setting (RMS) Range: 0.0μA~20.00mA, Resolution: 0.1μA/1μA/0.01mA
 
DC, 15Hz≤f≤100kHz: ±(1.5% × setting + 10 counts)
100kHz<f≤1000kHz: ±(5% × setting)
Contact current/leakage current upper/lower limit setting (peak) Range of upper/lower limit: 0.0pA~30.00mA,
Resolution: 0.1μA/1μA/0.01mA
DC: ±(2% × setting + 2 μA)
15Hz<f≤1000kHz: ±(10% × setting + 2 μA)
Contact current/leakage current upper/lower limit setting (AC component,optional for testing of medical device) Range: 0.0μA~20.00mA, 0.0μA~20.00mA, Resolution: 0.1μA/1μA/0.01mA
Accuracy: ±(3% × setting + 5 counts)
30Hz<f≤100kHz: ±(2% × setting + 3 counts)
100kHz<f≤1000kHz,10.0μA~999.9μA: ±(5% × setting)
1000μA~7999mA:15Hz≤f≤l00kHz: ±(2%× setting +3 counts)
100kHz<f≤1000kHz,10uA~7999μA: ±(5% × setting)
8.00mA~20.00mA:
15Hz≤f≤1000kHz, 0.01mA~20.00mA: ±(5% × setting)
Contact current/leakage current upper/lower limit setting (DC component,optional for testing of medical device Range: 0.0μA~20.00mA, Resolution: 0.1μA/1μA/0.01mA
0.0μA~999.9μA: ±(2% × setting + 3 counts)
1000μA~7999μA: ±(2% × setting +3 counts)
8.00mA~20.00mA: ±(5% × setting)
Test time Range: 0, (1~999.9), 0 is infinite, Resolution: 0.1s, ±(0.1% × setting + 2 count ),(when test method is AUTO(G-L、G-N),each gets half time)
Power parameter measurement Alarming function You can choose to set power, voltage or current
Power upper/lower limit setting(In fact, the upper limit is determined by the power of the power supply) Range: 0.10W~299.99W, 0.3000kW~1.4999kW, 1.500kW~10.000kW
Resolution: 0.01W/0.0001kW/0.001kW
PF>0.5: ±(0.1% × reading + 0.1% × measuring range)
PF≤0.5: ±(0.4% × reading + 0.1% × measuring range)
Voltage upper/lower limit setting When voltage alarm function is enabled
Range: 0.00V~300.0V, resolution: 0.01V/0.1V;
±(0.1% × setting + 0.1% × measuring range),
45Hz≤f≤65Hz
Current upper/lower limit setting (In fact, the upper limit is determined by the power of the power supply) When current alarm function is enabled
Range: 0.010A〜0.999A, 1.000A~4.999A, 5.00A-40.00A
Resolution: 0.001A, 0.01A
±(0.1% × setting + 0.1% × measuring range),45Hz≤f≤65Hz
Test time Range: 0,(0.5〜999.9)s, 0 is infinite,
Resolution: 0.1s,
±(0.1% × setting +2 count)
Low voltage starting test Current upper/lower limit setting Range: 0.010A~0.999A, 1.000A~4.999A, 5.00A~40.00A
Resolution: 0.001A, 0.01A
±(0.1% × setting + 0.1%× measuring range), 45Hz≤f≤65Hz
Voltage measurement Range: 10.00-300.00V,  peak factor: ≤1.6, Resolution:0.01V/0.1V;
±(0.1% × reading + 0.1% × range), 45Hz≤f≤65Hz
Current measurement Range: 0.010A~0.999A, 1.000A~4.999A, 5.00A~40.00A
Peak factor: ≤1.6, resolution: 0.001A, 0.01A;
±(0.1% × setting + 0.1% × measuring range), 45Hz≤f≤65Hz
Test time Range: 0,(0.5~9.999)s, 0 is infinite,
Resolution: 0.1s,
±(0.1% × setting + 2 count)
LN circuit detection Detection method DC constant current power supply
Resistance upper/lower limit setting Range:(1.0~999.9)Ω, Resolution: 0.1Ω,
±(2% × reading + 5 counts)
Test time Range: 0, (0.5~9.999)s, 0 is infinite,
Resolution: 0.1s,
±(0.1%×setting + 2 count)
Other configuration of equipment AN1651H(F) Built-in Ainuo 6kW variable frequency power supply
AN1640H(F) External isolated power supply or optional built-in 500W power supply is required
Dual station test Optional as required
Leakage test human simulation network Standard A//F/H common networks, other networks are optional
Dimensions 1640H(F) 426*177*550W×H×D,mm)
1651H(F) 483*1355*600W×H×D,mm)

 