The ANBGL(F) series Feedback AC Source Load combines the functions of both a grid simulation source and an AC load simulator, meeting a wide range of testing requirements in the new energy industry.
Source Mode is designed to comprehensively simulate grid characteristics, specifically developed for the photovoltaic, energy storage, and other new energy industries. It is suitable for grid adaptability testing of equipment connected to the grid, capable of providing stable voltage and frequency outputs, as well as supplying environments with various power quality characteristics such as voltage variations, frequency variations, harmonics, interharmonics, imbalance, flicker, etc., according to relevant standard requirements.
Load Mode offers multiple operating modes, including CC/CR/CP/CS/RLC, capable of simulating RLC, resistive, and switching loads. Compared with traditional passive loads, this unit integrates both AC source and load functions in one, with regenerative energy feedback to the grid. This significantly reduces customers' procurement costs and energy consumption, while aligning with the demands of a low-carbon society.
Built-in multiple RLC network models with adjustable parameters for simulating linear load characteristics.

Capable of simulating non-linear load characteristics.

Output voltage slew rate > 1V/μs, capable of realistically simulating 1ms grid interruption tests.

Support paralleling of up to 8 or more identical models for system expansion, with performance and accuracy comparable to a standalone.
Support 2nd to 50th harmonic superposition, interharmonics from 1 to 3,000Hz, and programmable waveform customization (sine, triangular, and user-defined waveforms).

Feature flicker, high/low voltage ride-through, and three-phase imbalance functions.

Meet the testing requirements of grid-following and grid-forming energy storage converters
Photovoltaic Grid-connected Inverter

AC/DC charging piles

Energy Storage System (ESS)

| Product Model | ANBGL200T-450(F) | ANBGL300T-450(F) | ANBGL400T-450(F) | ANBGL500T-450(F) | ANBGL600T-450(F) | ANBGL750T-450(F) | ANBGL1000T-450(F) | ANBGL1200T-450(F) | ANBGL1500T-450(F) | ||
| Power Supply Capacity | 200kVA | 300kVA | 400kVA | 500kVA | 600kVA | 750kVA | 1000kVA | 1200kVA | 1500kVA | ||
| Input Parameter | Voltage | Three-phase four-wire (ABC+PE); line voltage 380 V +/-15%, frequency 47-63 Hz | |||||||||
| Feedback Function | Energy regeneration to the grid | ||||||||||
| Power Factor *1 | >0.99 | ||||||||||
| Current Distortion *1 | <3% (at rated conditions) | ||||||||||
| Efficiency | ≥86% | ≥88% | ≥90% | ≥92% | |||||||
| AC Output | Output Mode | Three-phase four-wire standard mode; three-phase unbalance mode | |||||||||
| Output Wiring | Three-phase three-wire (ABC); three-phase four-wire (ABCN) | ||||||||||
| Voltage and Frequency | Phase voltage: 0.0 - 450.0V; Frequency 40.00 - 70.00Hz | ||||||||||
| RatedCurrent(RMS)(@166.6V) | 400.0A | 600.0A | 800.0A | 1000.0A | 1200.0A | 1500.0A | 2000.0A | 2400.0A | 3000.0A | ||
| Setting Accuracy | Voltage *2 | Resolution: 0.01V; Accuracy: 0.1% x F.S. | |||||||||
| Frequency | Resolution: 0.001Hz; Accuracy: 0.01% | ||||||||||
| Measurement Accuracy | Voltage *2 | Resolution: 0.01V; Accuracy: 0.1% x F.S. | |||||||||
| Frequency | Resolution: 0.001Hz; Accuracy: 0.01% | ||||||||||
| Current *3 | Resolution: 0.01A/0.1A/1A; Accuracy: 0.2% x F.S. | ||||||||||
| Power *4 | Resolution: 0.1kW/0.01 kW/0.001kW, Accuracy: 0.3% x F.S. | ||||||||||
| Frequency Stability | ≤0.01% | ||||||||||
| Voltage Distortion Degree*5 | <0.5% (50/60 Hz, 220 V, no load);<1% (linear load, >=220 V, 50 Hz) | ||||||||||
| Response Time | <1ms(10%-90%Umax) | ||||||||||
| Voltage Slew Rate | AC>1.0V/μs | ||||||||||
| Three-Phase Phase Difference | Three-phase standard mode: 120 degrees +/-0.3° | ||||||||||
| Three-phase unbalance mode: 0.0-359.9 degrees, adjustable in 0.1-degree steps | |||||||||||
| Phase Voltage Crest Factor | 1.41±0.1 | ||||||||||
| DC Component | <50mV | ||||||||||
| Line Regulation*6 | ≤0.02% | ||||||||||
| Load Regulation*7 | ≤0.02% | ||||||||||
| Overload Capability | 100% < output <=110%: 600s before output shutdown; 110% < output <=120% 60s before output shutdown; 120% < output <=150% 2s before output shutdown; 150% < output: immediate output shutdown. | ||||||||||
| Protection | IGBT overtemperature, IGBT overcurrent, transformer overtemperature, input overvoltage/undervoltage, DC bus overvoltage/undervoltage, output overvoltage/undervoltage, output phase loss, overcurrent, overload, and short circuit | ||||||||||
| Functions | Display | Color LCD with touch control | |||||||||
| Output Waveform | Sine wave, harmonics (2nd - 50th harmonic superimposition), interharmonics, and custom waveform | ||||||||||
| Voltage Transient Mode | Available; provides voltage steps (dips) from high to low voltage or low to high voltage | ||||||||||
| Flicker Mode | Available; any of 39 flicker parameter sets can be selected | ||||||||||
| High/Low (Zero) Voltage Ride-through Mode | Available; standard curves can be selected or customized to user requirements | ||||||||||
| Unbalance Mode | Available; each phase voltage and phase angle difference can be adjusted separately, or the three-phase unbalance can be set directly | ||||||||||
| Sequence Mode | 200 steps and 9,999 cycles; voltage, frequency, and phase angle are freely programmable; custom waveform programming | ||||||||||
| Impedance Sweep | 1 - 3000Hz; step/ramp selectable | ||||||||||
| Damping Control | Supported | ||||||||||
| SCR Simulation | 1-10; X/R ratio adjustable | ||||||||||
| Soft-Start Ramp Time | 0.0 - 99.9 s | ||||||||||
| On-the-Fly Adjustment | In normal mode, output voltage and frequency can be adjusted, and waveforms can be switched during operation | ||||||||||
| Memory | Power-loss memory retains the last output mode and parameters | ||||||||||
| Communication Interfaces | RS485 (standard), RS232 (optional), GPIB (optional), LAN (standard), sync signal (standard) | ||||||||||
| Noise | ≤ 80dB | ||||||||||
| Parallel Operation | Supports parallel operation of at least eight units of the same model | ||||||||||
| Dielectric Withstand Voltage | 10MΩ/DC 500V 3600VAC/1min | ||||||||||
| Environment | Temperature and Humidity | -10-40 degrees C (derating required above 40 degrees C), 10 - 90%RH | |||||||||
| Dimensions (W*H*D mm) Modular Cabinet (including a base height of 100) | 1500*1900*1200 | 2400*1900 *1200 | 3400*1900*1400 | 3400*2100*1600 | 4400*2100*1600 | ||||||
| Dimensions (W*H*D mm) Integrated base; supports forklift handling and lifting (including a base height of 100) | / | 3400*2180*1400 | 3400*2380*1600 | 4400*2380*1600 | |||||||
| Weight | ≤2300kg | ≤3000kg | ≤3500kg | ≤4900kg | ≤5300kg | ≤5700kg | ≤7500kg | ≤8500kg | ≤9500kg | ||
Notes:*1. Power factor and current distortion are measured at a rated input voltage of 380 VLL using a resistive load at rated output power.
*2. For voltage-related parameters in the table, F.S. refers to the applicable maximum AC output voltage specified by the voltage measurement range of the corresponding model.
*3. For current-related parameters in the table, F.S. refers to the maximum measurable RMS current specified by the rzuzvujaotlxq wstni'z current measurement range.
*4. For power-related parameters in the table, F.S. refers to the maximum measurable power of the corresponding model.
*5. Voltage distortion is measured at an output voltage of 166.6 V with a linear load.
*6. Line regulation is calculated from no-load output-voltage measurements at input voltages of 380 VLL and 420 VLL.
*7. Load regulation at 166.6 V is calculated from the no-load output voltage and the output voltage measured with a resistive load at rated power.
| Product Model | ANBGL300T-900(F) | ANBGL400T-900(F) | ANBGL500T-900(F) | ANBGL600T-900(F) | ANBGL750T-900(F) | ANBGL1000T-900(F) | ANBGL1200T-450(F) | ANBGL1500T-450(F) | ||
| Power Supply Capacity | 300kVA | 400kVA | 500kVA | 600kVA | 750kVA | 1000kVA | 1200kVA | 1500kVA | ||
| Input Parameter | Voltage | Three-phase four-wire (ABC+PE); line voltage 380 V +/-15%, frequency 47-63 Hz | ||||||||
| Feedback Function | Energy regeneration to the grid | |||||||||
| Power Factor *1 | >0.99 | |||||||||
| Current Distortion *1 | <3% (at rated conditions) | |||||||||
| Efficiency | ≥88% | ≥90% | ≥92% | |||||||
| AC Output | Output Mode | Three-phase four-wire standard mode; three-phase unbalance mode | ||||||||
| Output Wiring | Three-phase three-wire (ABC); three-phase four-wire (ABCN) | |||||||||
| Voltage and Frequency | Phase voltage: 0.0 - 450.0V; Frequency 40.00 - 70.00Hz | |||||||||
| RatedCurrent(RMS)(@333.3V) | 300.0A | 400.0A | 500.0A | 600.0A | 750.0A | 1000.0A | 1200.0A | 1500.0A | ||
| Setting Accuracy | Voltage *2 | Resolution: 0.01V; Accuracy: 0.1% x F.S. | ||||||||
| Frequency | Resolution: 0.001Hz; Accuracy: 0.01% | |||||||||
| Measurement Accuracy | Voltage *2 | Resolution: 0.01V; Accuracy: 0.1% x F.S. | ||||||||
| Frequency | Resolution: 0.001Hz; Accuracy: 0.01% | |||||||||
| Current *3 | Resolution: 0.01A/0.1A/1A; Accuracy: 0.2% x F.S. | |||||||||
| Power *4 | Resolution: 0.1kW/0.01 kW/0.001kW, Accuracy: 0.3% x F.S. | |||||||||
| Frequency Stability | ≤0.01% | |||||||||
| Voltage Distortion Degree*5 | <0.5% (50/60 Hz, 220 V, no load);<1% (linear load, >=220 V, 50 Hz) | |||||||||
| Response Time | <1ms(10%-90%Umax) | |||||||||
| Voltage Slew Rate | AC>1.0V/μs | |||||||||
| Three-Phase Phase Difference | Three-phase standard mode: 120 degrees +/-0.3° | |||||||||
| Three-phase unbalance mode: 0.0-359.9 degrees, adjustable in 0.1-degree steps | ||||||||||
| Phase Voltage Crest Factor | 1.41±0.1 | |||||||||
| DC Component | <50mV | |||||||||
| Line Regulation*6 | ≤0.02% | |||||||||
| Load Regulation*7 | ≤0.02% | |||||||||
| Overload Capability | 100% < output <=110%: 600s before output shutdown; 110% < output <=120% 60s before output shutdown; 120% < output <=150% 2s before output shutdown; 150% < output: immediate output shutdown. | |||||||||
| Protection | IGBT overtemperature, IGBT overcurrent, transformer overtemperature, input overvoltage/undervoltage, DC bus overvoltage/undervoltage, output overvoltage/undervoltage, output phase loss, overcurrent, overload, and short circuit | |||||||||
| Functions | Display | Color LCD with touch control | ||||||||
| Output Waveform | Sine wave, harmonics (2nd - 50th harmonic superimposition), interharmonics, and custom waveform | |||||||||
| Voltage Transient Mode | Available; provides voltage steps (dips) from high to low voltage or low to high voltage | |||||||||
| Flicker Mode | Available; any of 39 flicker parameter sets can be selected | |||||||||
| High/Low (Zero) Voltage Ride-through Mode | Available; standard curves can be selected or customized to user requirements | |||||||||
| Unbalance Mode | Available; each phase voltage and phase angle difference can be adjusted separately, or the three-phase unbalance can be set directly | |||||||||
| Sequence Mode | 200 steps and 9,999 cycles; voltage, frequency, and phase angle are freely programmable; custom waveform programming | |||||||||
| Impedance Sweep | 1 - 3000Hz; step/ramp selectable | |||||||||
| Damping Control | Supported | |||||||||
| SCR Simulation | 1-10; X/R ratio adjustable | |||||||||
| Soft-Start Ramp Time | 0.0 - 99.9 s | |||||||||
| On-the-Fly Adjustment | In normal mode, output voltage and frequency can be adjusted, and waveforms can be switched during operation | |||||||||
| Memory | Power-loss memory retains the last output mode and parameters | |||||||||
| Communication Interfaces | RS485 (standard), RS232 (optional), GPIB (optional), LAN (standard), sync signal (standard) | |||||||||
| Noise | ≤ 80dB | |||||||||
| Parallel Operation | Supports parallel operation of at least eight units of the same model | |||||||||
| Dielectric Withstand Voltage | 10MΩ/DC 500V 3600VAC/1min | |||||||||
| Environment | Temperature and Humidity | -10-40 degrees C (derating required above 40 degrees C), 10 - 90%RH | ||||||||
| Dimensions (W*H*D mm) Modular Cabinet (including a base height of 100) | 2400*1900 *1200 | 3400*1900*1400 | 3400*2100*1400 | 3400*2100*1600 | 4400*2100*1600 | |||||
| Dimensions (W*H*D mm) Integrated base; supports forklift handling and lifting (including a base height of 100) | / | 3400*2180*1400 | 3400*2380*1400 | 3400*2380*1600 | 4400*2380*1600 | |||||
| Weight | ≤3100kg | ≤3300kg | ≤3500kg | ≤5100kg | ≤5500kg | ≤7300kg | ≤8300kg | ≤9000kg | ||
Notes:*1. Power factor and current distortion are measured at a rated input voltage of 380 VLL using a resistive load at rated output power.
*2. For voltage-related parameters in the table, F.S. refers to the applicable maximum AC output voltage specified by the voltage measurement range of the corresponding model.
*3. For current-related parameters in the table, F.S. refers to the maximum measurable RMS current specified by the corresponding model's current measurement range.
*4. For power-related parameters in the table, F.S. refers to the maximum measurable power of the corresponding model.
*5. Voltage distortion is measured at an output voltage of 333.3 V with a linear load.
*6. Line regulation is calculated from no-load output-voltage measurements at input voltages of 380 VLL and 420 VLL.
*7. Load regulation at 333.3 V is calculated from the no-load output voltage and the output voltage measured with a resistive load at rated power.
| Product Model | ANBGL200T-450(F) | ANBGL300T-450(F) | ANBGL400T-450(F) | ANBGL500T-450(F) | ANBGL600T-450(F) | ANBGL750T-450(F) | ANBGL1000T-450(F) | ANBGL1200T-450(F) | ANBGL1500T-450(F) | ||
| Capacity | 200kVA | 300kVA | 400kVA | 500kVA | 600kVA | 750kVA | 1000kVA | 1200kVA | 1500kVA | ||
| Output Wiring Mode | Three-phase three-wire (ABC); three-phase four-wire (ABC+N) | ||||||||||
| Operating Load Input (per phase) | Voltage Range | 50~450V | |||||||||
| Current Range (RMS) | 400.0A | 600.0A | 800.0A | 1000.0A | 1200.0A | 1500.0A | 2000.0A | 2400.0A | 3000.0A | ||
| Crest Factor | 1.414~4 | ||||||||||
| Frequency Range | 40 - 70Hz | ||||||||||
| Allowable Voltage Distortion | Uthd <10%, up to the 20th harmonic | ||||||||||
CC/Constant Current Mode (Per Phase) | Current | Setting Range | 0-400.0A | 0-600.0A | 0-800.0A | 0-1000.0A | 0-1200.0A | 0-1500.0A | 0-2000.0A | 0-2400.0A | 0-3000.0A |
| Resolution | 0.01A | ||||||||||
| Accuracy | 0.2% * F.S. (above 50 A) | ||||||||||
| Distortion | <2% @ 50 Hz @ rated voltage and full load | ||||||||||
| Waveform | Sine, square, triangle, and custom waveforms | ||||||||||
| Current Slew Rate | 10%-90% rated current: >1 A/μs | ||||||||||
| Dynamic Response | <1 ms @ 10%-90% rated current | ||||||||||
| Harmonic Limits | 2nd-10th: max. 40% each; total <=50%; 11th-20th: max. 20% each; total <=20%; 21st-30th: max. 10% each; total <=10%; 31st-50th: max. 5% each; total <=10% | ||||||||||
CP Constant Active Power Mode (Per Phase) | Power | Range | 0-66.6kW | 0-100.0kW | 0-133.3kW | 0-166.6kW | 0-200.0kW | 0-250.0kW | 0-333.3kW | 0-400.0kW | 0-500.0kW |
| Resolution | 0.1kW | ||||||||||
| Accuracy | 0.5% x F.S. (above 5 kW) | ||||||||||
CS Constant Apparent Power Mode (Per Phase) | Power | Range | 0-66.6kVA | 0-100.0kVA | 0-133.3kVA | 0-166.6kVA | 0-200.0kVA | 0-250.0kVA | 0-333.3kVA | 0-400.0kVA | 0-500.0kVA |
| Resolution | 0.1kVA | ||||||||||
| Accuracy | 0.5% x F.S. (above 5 kVA) | ||||||||||
CR Constant Resistance Mode (Per Phase) | Resistance | Range | 0.1Ω - 50Ω | ||||||||
| Resolution | 0.01Ω | ||||||||||
| Accuracy | 0.2% x F.S.(above 50A) | ||||||||||
RLC Mode (Per Phase) | Resistance R | Range | 0.1Ω - 50Ω | ||||||||
| Resolution | 0.01Ω | ||||||||||
Inductance L | Range | 50μH - 35mH | |||||||||
| Resolution | 1μH | ||||||||||
Capacitance C | Range | 50μF - 250mF | |||||||||
| Resolution | 1μF | ||||||||||
| RLC | R+L+C, R//L//C, (R//C)+L, (R+L)//C, (R+C)//L Resistance, inductance, and capacitance are adjustable | ||||||||||
*The above specifications are subject to change without notice.
| Product Model | ANBGL300T-900(F) | ANBGL400T-900(F) | ANBGL500T-900(F) | ANBGL600T-900(F) | ANBGL750T-900(F) | ANBGL1000T-900(F) | ANBGL1200T-900(F) | ANBGL1500T-900(F) | ||
| Capacity | 300kVA | 400kVA | 500kVA | 600kVA | 750kVA | 1000kVA | 1200kVA | 1500kVA | ||
| Output Wiring Mode | Three-phase three-wire (ABC); three-phase four-wire (ABC+N) | |||||||||
| Operating Load Input (per phase) | Voltage Range | 50~900V | ||||||||
| Current Range (RMS) | 300.0A | 400.0A | 500.0A | 600.0A | 750.0A | 1000.0A | 1200.0A | 1500.0A | ||
| Crest Factor | 1.414~4 | |||||||||
| Frequency Range | 40 - 70Hz | |||||||||
| Allowable Voltage Distortion | Uthd <10%, up to the 20th harmonic | |||||||||
CC/Constant Current Mode (Per Phase) | Current | Setting Range | 0-300.0A | 0-400.0A | 0-500.0A | 0-600.0A | 0-750.0A | 0-1000.0A | 0-1200.0A | 0-1500.0A |
| Resolution | 0.01A | |||||||||
| Accuracy | 0.2% * F.S. (above 50 A) | |||||||||
| Distortion | <2% @ 50 Hz @ rated voltage and full load | |||||||||
| Waveform | Sine, square, triangle, and custom waveforms | |||||||||
| Current Slew Rate | 10%-90% rated current: >1 A/μs | |||||||||
| Dynamic Response | <1 ms @ 10%-90% rated current | |||||||||
| Harmonic Limits | 2nd-10th: max. 40% each; total <=50%; 11th-20th: max. 20% each; total <=20%; 21st-30th: max. 10% each; total <=10%; 31st-50th: max. 5% each; total <=10% | |||||||||
CP Constant Active Power Mode (Per Phase) | Power | Range | 0-100.0kW | 0-133.3kW | 0-166.6kW | 0-200.0kW | 0-250.0kW | 0-333.3kW | 0-400.0kW | 0-500.0kW |
| Resolution | 0.1kW | |||||||||
| Accuracy | 0.5% x F.S. (above 5 kW) | |||||||||
CS Constant Apparent Power Mode (Per Phase) | Power | Range | 0-100.0kVA | 0-133.3kVA | 0-166.6kVA | 0-200.0kVA | 0-250.0kVA | 0-333.3kVA | 0-400.0kVA | 0-500.0kVA |
| Resolution | 0.1kVA | |||||||||
| Accuracy | 0.5% x F.S. (above 5 kVA) | |||||||||
CR Constant Resistance Mode (Per Phase) | Resistance | Range | 0.1Ω - 50Ω | |||||||
| Resolution | 0.01Ω | |||||||||
| Accuracy | 0.2% x F.S.(above 50A) | |||||||||
RLC Mode (Per Phase) | Resistance R | Range | 0.1Ω - 50Ω | |||||||
| Resolution | 0.01Ω | |||||||||
Inductance L | Range | 50μH - 35mH | ||||||||
| Resolution | 1μH | |||||||||
Capacitance C | Range | 50μF - 250mF | ||||||||
| Resolution | 1μF | |||||||||
| RLC | R+L+C, R//L//C, (R//C)+L, (R+L)//C, (R+C)//L Resistance, inductance, and capacitance are adjustable | |||||||||
*The above specifications are subject to change without notice.