ANBGL(F) Series Feedback AC Source Load - Ainuo Instrument
Home   >   Products>Power Supplies & E-Loads>AC Power Source>AC Grid Simulation Power Source>ANBGL(F) Feedback AC Source & Load

ANBGL(F) Series Feedback AC Source Load

Model:
ANBGL(F)
Application:
Suitable for testing photovoltaic grid-connected inverters, AC/DC charging piles, and energy storage systems (ESS).
Product overview Product features Product application Technical specifications
Product overview

The ANBGL(F) series Feedback AC Source Load combines the functions of both a grid simulation source and an AC load simulator, meeting a wide range of testing requirements in the new energy industry. 

Source Mode is designed to comprehensively simulate grid characteristics, specifically developed for the photovoltaic, energy storage, and other new energy industries. It is suitable for grid adaptability testing of equipment connected to the grid, capable of providing stable voltage and frequency outputs, as well as supplying environments with various power quality characteristics such as voltage variations, frequency variations, harmonics, interharmonics, imbalance, flicker, etc., according to relevant standard requirements.

Load Mode offers multiple operating modes, including CC/CR/CP/CS/RLC, capable of simulating RLC, resistive, and switching loads. Compared with traditional passive loads, this unit integrates both AC source and load functions in one, with regenerative energy feedback to the grid. This significantly reduces customers' procurement costs and energy consumption, while aligning with the demands of a low-carbon society.

Product features

Built-in multiple RLC network models with adjustable parameters for simulating linear load characteristics.

Built-in multiple RLC network models

Capable of simulating non-linear load characteristics.

capable of simulating non-linear load

Output voltage slew rate > 1V/μs, capable of realistically simulating 1ms grid interruption tests.

1ms grid interruption simulation

Support paralleling of up to 8 or more identical models for system expansion, with performance and accuracy comparable to a standalone.

Support 2nd to 50th harmonic superposition, interharmonics from 1 to 3,000Hz, and programmable waveform customization (sine, triangular, and user-defined waveforms).

2-50 harmonic superposition

Feature flicker, high/low voltage ride-through, and three-phase imbalance functions.

Flicker

Meet the testing requirements of grid-following and grid-forming energy storage converters

Product application

Photovoltaic Grid-connected Inverter

pv grid-connected inverter

AC/DC charging piles

AC/DC charging piles

Energy Storage System (ESS)

energy storage system

Technical specifications
Product ModelANBGL200T-450(F)ANBGL300T-450(F)ANBGL400T-450(F)ANBGL500T-450(F)ANBGL600T-450(F)ANBGL750T-450(F)ANBGL1000T-450(F)ANBGL1200T-450(F)ANBGL1500T-450(F)
Power Supply Capacity200kVA300kVA400kVA500kVA600kVA750kVA1000kVA1200kVA1500kVA
Input ParameterVoltageThree-phase four-wire (ABC+PE); line voltage 380 V +/-15%, frequency 47-63 Hz
Feedback FunctionEnergy regeneration to the grid
Power Factor *1>0.99
Current Distortion *1<3% (at rated conditions)
Efficiency≥86%≥88%≥90%≥92%
AC OutputOutput ModeThree-phase four-wire standard mode; three-phase unbalance mode
Output WiringThree-phase three-wire (ABC); three-phase four-wire (ABCN)
Voltage and FrequencyPhase voltage: 0.0 - 450.0V; Frequency 40.00 - 70.00Hz
RatedCurrent(RMS)(@166.6V)400.0A600.0A800.0A1000.0A1200.0A1500.0A2000.0A2400.0A3000.0A
Setting AccuracyVoltage *2Resolution: 0.01V; Accuracy: 0.1% x F.S.
FrequencyResolution: 0.001Hz; Accuracy: 0.01%
Measurement AccuracyVoltage *2Resolution: 0.01V; Accuracy: 0.1% x F.S.
FrequencyResolution: 0.001Hz; Accuracy: 0.01%
Current *3Resolution: 0.01A/0.1A/1A; Accuracy: 0.2% x F.S.
Power *4Resolution: 0.1kW/0.01 kW/0.001kW, Accuracy: 0.3% x F.S.
Frequency Stability≤0.01%
Voltage Distortion Degree*5<0.5% (50/60 Hz, 220 V, no load);<1% (linear load, >=220 V, 50 Hz)
Response Time<1ms(10%-90%Umax)
Voltage Slew RateAC>1.0V/μs
Three-Phase Phase DifferenceThree-phase standard mode: 120 degrees +/-0.3°
Three-phase unbalance mode: 0.0-359.9 degrees, adjustable in 0.1-degree steps
Phase Voltage Crest Factor1.41±0.1
DC Component<50mV
Line Regulation*6≤0.02%
Load Regulation*7≤0.02%
Overload Capability

100% < output <=110%: 600s before output shutdown;

110% < output <=120% 60s before output shutdown;

120% < output <=150% 2s before output shutdown;

150% < output: immediate output shutdown.

ProtectionIGBT overtemperature, IGBT overcurrent, transformer overtemperature, input overvoltage/undervoltage, DC bus overvoltage/undervoltage, output overvoltage/undervoltage, output phase loss, overcurrent, overload, and short circuit
FunctionsDisplayColor LCD with touch control
Output WaveformSine wave, harmonics (2nd - 50th harmonic superimposition), interharmonics, and custom waveform
Voltage Transient ModeAvailable; provides voltage steps (dips) from high to low voltage or low to high voltage
Flicker ModeAvailable; any of 39 flicker parameter sets can be selected
High/Low (Zero) Voltage Ride-through ModeAvailable; standard curves can be selected or customized to user requirements
Unbalance ModeAvailable; each phase voltage and phase angle difference can be adjusted separately, or the three-phase unbalance can be set directly
Sequence Mode200 steps and 9,999 cycles; voltage, frequency, and phase angle are freely programmable; custom waveform programming
Impedance Sweep1 - 3000Hz; step/ramp selectable
Damping ControlSupported
SCR Simulation1-10; X/R ratio adjustable
Soft-Start Ramp Time0.0 - 99.9 s
On-the-Fly AdjustmentIn normal mode, output voltage and frequency can be adjusted, and waveforms can be switched during operation
MemoryPower-loss memory retains the last output mode and parameters
Communication InterfacesRS485 (standard), RS232 (optional), GPIB (optional), LAN (standard), sync signal (standard)
Noise≤ 80dB
Parallel OperationSupports parallel operation of at least eight units of the same model
Dielectric Withstand Voltage10MΩ/DC 500V 3600VAC/1min
EnvironmentTemperature and Humidity-10-40 degrees C (derating required above 40 degrees C), 10 - 90%RH
Dimensions (W*H*D mm) Modular Cabinet (including a base height of 100)1500*1900*1200

2400*1900 *1200

3400*1900*14003400*2100*16004400*2100*1600
Dimensions (W*H*D mm) Integrated base; supports forklift handling and lifting (including a base height of 100)/3400*2180*14003400*2380*16004400*2380*1600
Weight≤2300kg≤3000kg≤3500kg≤4900kg≤5300kg≤5700kg≤7500kg≤8500kg≤9500kg

Notes:*1. Power factor and current distortion are measured at a rated input voltage of 380 VLL using a resistive load at rated output power.

*2. For voltage-related parameters in the table, F.S. refers to the applicable maximum AC output voltage specified by the voltage measurement range of the corresponding model.

*3. For current-related parameters in the table, F.S. refers to the maximum measurable RMS current specified by the rzuzvujaotlxq wstni'z current measurement range.

*4. For power-related parameters in the table, F.S. refers to the maximum measurable power of the corresponding model.

*5. Voltage distortion is measured at an output voltage of 166.6 V with a linear load.

*6. Line regulation is calculated from no-load output-voltage measurements at input voltages of 380 VLL and 420 VLL.

*7. Load regulation at 166.6 V is calculated from the no-load output voltage and the output voltage measured with a resistive load at rated power.


Product ModelANBGL300T-900(F)ANBGL400T-900(F)ANBGL500T-900(F)ANBGL600T-900(F)ANBGL750T-900(F)ANBGL1000T-900(F)ANBGL1200T-450(F)ANBGL1500T-450(F)
Power Supply Capacity300kVA400kVA500kVA600kVA750kVA1000kVA1200kVA1500kVA
Input ParameterVoltageThree-phase four-wire (ABC+PE); line voltage 380 V +/-15%, frequency 47-63 Hz
Feedback FunctionEnergy regeneration to the grid
Power Factor *1>0.99
Current Distortion *1<3% (at rated conditions)
Efficiency≥88%≥90%≥92%
AC OutputOutput ModeThree-phase four-wire standard mode; three-phase unbalance mode
Output WiringThree-phase three-wire (ABC); three-phase four-wire (ABCN)
Voltage and FrequencyPhase voltage: 0.0 - 450.0V; Frequency 40.00 - 70.00Hz
RatedCurrent(RMS)(@333.3V)300.0A400.0A500.0A600.0A750.0A1000.0A1200.0A1500.0A
Setting AccuracyVoltage *2Resolution: 0.01V; Accuracy: 0.1% x F.S.
FrequencyResolution: 0.001Hz; Accuracy: 0.01%
Measurement AccuracyVoltage *2Resolution: 0.01V; Accuracy: 0.1% x F.S.
FrequencyResolution: 0.001Hz; Accuracy: 0.01%
Current *3Resolution: 0.01A/0.1A/1A; Accuracy: 0.2% x F.S.
Power *4Resolution: 0.1kW/0.01 kW/0.001kW, Accuracy: 0.3% x F.S.
Frequency Stability≤0.01%
Voltage Distortion Degree*5<0.5% (50/60 Hz, 220 V, no load);<1% (linear load, >=220 V, 50 Hz)
Response Time<1ms(10%-90%Umax)
Voltage Slew RateAC>1.0V/μs
Three-Phase Phase DifferenceThree-phase standard mode: 120 degrees +/-0.3°
Three-phase unbalance mode: 0.0-359.9 degrees, adjustable in 0.1-degree steps
Phase Voltage Crest Factor1.41±0.1
DC Component<50mV
Line Regulation*6≤0.02%
Load Regulation*7≤0.02%
Overload Capability

100% < output <=110%: 600s before output shutdown;

110% < output <=120% 60s before output shutdown;

120% < output <=150% 2s before output shutdown;

150% < output: immediate output shutdown.

ProtectionIGBT overtemperature, IGBT overcurrent, transformer overtemperature, input overvoltage/undervoltage, DC bus overvoltage/undervoltage, output overvoltage/undervoltage, output phase loss, overcurrent, overload, and short circuit
FunctionsDisplayColor LCD with touch control
Output WaveformSine wave, harmonics (2nd - 50th harmonic superimposition), interharmonics, and custom waveform
Voltage Transient ModeAvailable; provides voltage steps (dips) from high to low voltage or low to high voltage
Flicker ModeAvailable; any of 39 flicker parameter sets can be selected
High/Low (Zero) Voltage Ride-through ModeAvailable; standard curves can be selected or customized to user requirements
Unbalance ModeAvailable; each phase voltage and phase angle difference can be adjusted separately, or the three-phase unbalance can be set directly
Sequence Mode200 steps and 9,999 cycles; voltage, frequency, and phase angle are freely programmable; custom waveform programming
Impedance Sweep1 - 3000Hz; step/ramp selectable
Damping ControlSupported
SCR Simulation1-10; X/R ratio adjustable
Soft-Start Ramp Time0.0 - 99.9 s
On-the-Fly AdjustmentIn normal mode, output voltage and frequency can be adjusted, and waveforms can be switched during operation
MemoryPower-loss memory retains the last output mode and parameters
Communication InterfacesRS485 (standard), RS232 (optional), GPIB (optional), LAN (standard), sync signal (standard)
Noise≤ 80dB
Parallel OperationSupports parallel operation of at least eight units of the same model
Dielectric Withstand Voltage10MΩ/DC 500V 3600VAC/1min
EnvironmentTemperature and Humidity-10-40 degrees C (derating required above 40 degrees C), 10 - 90%RH
Dimensions (W*H*D mm) Modular Cabinet (including a base height of 100)

2400*1900 *1200

3400*1900*14003400*2100*14003400*2100*16004400*2100*1600
Dimensions (W*H*D mm) Integrated base; supports forklift handling and lifting (including a base height of 100)/3400*2180*14003400*2380*14003400*2380*16004400*2380*1600
Weight≤3100kg≤3300kg≤3500kg≤5100kg≤5500kg≤7300kg≤8300kg≤9000kg

Notes:*1. Power factor and current distortion are measured at a rated input voltage of 380 VLL using a resistive load at rated output power.

*2. For voltage-related parameters in the table, F.S. refers to the applicable maximum AC output voltage specified by the voltage measurement range of the corresponding model.

*3. For current-related parameters in the table, F.S. refers to the maximum measurable RMS current specified by the corresponding model's current measurement range.

*4. For power-related parameters in the table, F.S. refers to the maximum measurable power of the corresponding model.

*5. Voltage distortion is measured at an output voltage of 333.3 V with a linear load.

*6. Line regulation is calculated from no-load output-voltage measurements at input voltages of 380 VLL and 420 VLL.

*7. Load regulation at 333.3 V is calculated from the no-load output voltage and the output voltage measured with a resistive load at rated power.


Product ModelANBGL200T-450(F)ANBGL300T-450(F)ANBGL400T-450(F)ANBGL500T-450(F)ANBGL600T-450(F)ANBGL750T-450(F)ANBGL1000T-450(F)ANBGL1200T-450(F)ANBGL1500T-450(F)
Capacity200kVA300kVA400kVA500kVA600kVA750kVA1000kVA1200kVA1500kVA
Output Wiring ModeThree-phase three-wire (ABC); three-phase four-wire (ABC+N)
Operating Load Input (per phase)Voltage Range50~450V
Current Range (RMS)400.0A600.0A800.0A1000.0A1200.0A1500.0A2000.0A2400.0A3000.0A
Crest Factor1.414~4
Frequency Range40 - 70Hz
Allowable Voltage DistortionUthd <10%, up to the 20th harmonic

CC/Constant

Current

Mode (Per

Phase)

CurrentSetting Range0-400.0A0-600.0A0-800.0A0-1000.0A0-1200.0A0-1500.0A0-2000.0A0-2400.0A0-3000.0A
Resolution0.01A
Accuracy0.2% * F.S. (above 50 A)
Distortion<2% @ 50 Hz @ rated voltage and full load
WaveformSine, square, triangle, and custom waveforms
Current Slew Rate10%-90% rated current: >1 A/μs
Dynamic Response<1 ms @ 10%-90% rated current
Harmonic Limits2nd-10th: max. 40% each; total <=50%; 11th-20th: max. 20% each; total <=20%;

21st-30th: max. 10% each; total <=10%; 31st-50th: max. 5% each; total <=10%

CP Constant

Active

Power Mode

(Per Phase)

PowerRange0-66.6kW0-100.0kW0-133.3kW0-166.6kW0-200.0kW0-250.0kW0-333.3kW0-400.0kW0-500.0kW
Resolution0.1kW
Accuracy0.5% x F.S. (above 5 kW)

CS Constant

Apparent

Power Mode

(Per Phase)

PowerRange0-66.6kVA0-100.0kVA0-133.3kVA0-166.6kVA0-200.0kVA0-250.0kVA0-333.3kVA0-400.0kVA0-500.0kVA
Resolution0.1kVA
Accuracy0.5% x F.S. (above 5 kVA)

CR Constant

Resistance

Mode (Per

Phase)

ResistanceRange0.1Ω - 50Ω
Resolution0.01Ω
Accuracy0.2% x F.S.(above 50A)

RLC Mode

(Per Phase)

Resistance

R

Range0.1Ω - 50Ω
Resolution0.01Ω

Inductance

L

Range50μH - 35mH
Resolution1μH

Capacitance

C

Range50μF - 250mF
Resolution1μF
RLCR+L+C, R//L//C, (R//C)+L, (R+L)//C, (R+C)//L Resistance, inductance, and capacitance are adjustable

*The above specifications are subject to change without notice.


Product ModelANBGL300T-900(F)ANBGL400T-900(F)ANBGL500T-900(F)ANBGL600T-900(F)ANBGL750T-900(F)ANBGL1000T-900(F)ANBGL1200T-900(F)ANBGL1500T-900(F)
Capacity300kVA400kVA500kVA600kVA750kVA1000kVA1200kVA1500kVA
Output Wiring ModeThree-phase three-wire (ABC); three-phase four-wire (ABC+N)
Operating Load Input (per phase)Voltage Range50~900V
Current Range (RMS)300.0A400.0A500.0A600.0A750.0A1000.0A1200.0A1500.0A
Crest Factor1.414~4
Frequency Range40 - 70Hz
Allowable Voltage DistortionUthd <10%, up to the 20th harmonic

CC/Constant

Current

Mode (Per

Phase)

CurrentSetting Range0-300.0A0-400.0A0-500.0A0-600.0A0-750.0A0-1000.0A0-1200.0A0-1500.0A
Resolution0.01A
Accuracy0.2% * F.S. (above 50 A)
Distortion<2% @ 50 Hz @ rated voltage and full load
WaveformSine, square, triangle, and custom waveforms
Current Slew Rate10%-90% rated current: >1 A/μs
Dynamic Response<1 ms @ 10%-90% rated current
Harmonic Limits2nd-10th: max. 40% each; total <=50%; 11th-20th: max. 20% each; total <=20%;

21st-30th: max. 10% each; total <=10%; 31st-50th: max. 5% each; total <=10%

CP Constant

Active

Power Mode

(Per Phase)

PowerRange0-100.0kW0-133.3kW0-166.6kW0-200.0kW0-250.0kW0-333.3kW0-400.0kW0-500.0kW
Resolution0.1kW
Accuracy0.5% x F.S. (above 5 kW)

CS Constant

Apparent

Power Mode

(Per Phase)

PowerRange0-100.0kVA0-133.3kVA0-166.6kVA0-200.0kVA0-250.0kVA0-333.3kVA0-400.0kVA0-500.0kVA
Resolution0.1kVA
Accuracy0.5% x F.S. (above 5 kVA)

CR Constant

Resistance

Mode (Per

Phase)

ResistanceRange0.1Ω - 50Ω
Resolution0.01Ω
Accuracy0.2% x F.S.(above 50A)

RLC Mode

(Per Phase)

Resistance

R

Range0.1Ω - 50Ω
Resolution0.01Ω

Inductance

L

Range50μH - 35mH
Resolution1μH

Capacitance

C

Range50μF - 250mF
Resolution1μF
RLCR+L+C, R//L//C, (R//C)+L, (R+L)//C, (R+C)//L Resistance, inductance, and capacitance are adjustable

*The above specifications are subject to change without notice.