Water-Cooled Bidirectional Programmable DC Power Supply ANEVH LC(F) - Ainuo Instrument
Home   >   Products>Power Supplies & E-Loads>DC Power Supply>Programmable Bidirectional DC Power Supply>ANEVH LC(F) Water-cooled Bidirectional Programmable DC Power Supply

Water-Cooled Bidirectional Programmable DC Power Supply ANEVH LC(F)

Model:
ANEVH LC(F)
Application:
Suitable for testing automotive electronics, new energy three-power, micro-grid, high-power test and other applications.
Product overview Product features Product application Technical specifications
Product overview

The brand-new ANEVH LC(F) series water-cooled bidirectional programmable DC power supply adopts a high-frequency modular design, offering high power density; adopts soft-switching resonant conversion technology, reduces losses and improves efficiency; the power supply features functions such as battery simulation, electronic load, PV simulation, and waveform editing (LIST), it serves not only as a power source to deliver energy but also as a load to absorb energy in reverse and return it cleanly to the grid, fully supporting standard bidirectional operation.

Product features
  • Ultra-high power density: 4U height, up to 40 kW per unit, 720 kW/m3;

  • Water-cooled heat dissipation: dust-free and silent, strong adaptability to harsh environments, reducing air-conditioning costs;

  • 8.8-inch color touchscreen for easy and intuitive operation;

  • All-in-one unit integrating PV simulation, battery simulation, and electronic load;

  • Source and load functions integrated in a high-frequency modular design;

  • Multiple modules can be paralleled for flexible power expansion;

  • High-frequency PWM rectification and bidirectional DCDC technology to eliminate high-frequency noise in high-power bidirectional supplies;

  • SiC devices for higher power density, smaller size, and faster response;

  • Bidirectional energy flow with automatic seamless switching between forward and reverse modes;

  • Efficiency up to 95%, offering outstanding advantages in energy saving and environmental friendliness;

  • Sense terminal compensation to compensate for cable voltage drop;

  • Built-in function generator supporting arbitrary waveform generation;

  • Comprehensive protections: OTP, OVP, OCP, OPP, overtemperature, islanding protection, AC input over/undervoltage protection, etc.

flexible paralleling


Product application

The power modules support master/slave parallel operation, enabling flexible power expansion to form higher-power systems. They feature programmable capability, allowing the generation of arbitrary waveforms to meet a wide range of testing requirements. They are equipped with comprehensive protection functions, including input undervoltage, output overvoltage, output overcurrent, output overpower, and internal overtemperature protection, ensuring reliable and stable power supply operation.

Technical specifications
ModelANEVH500-240 LC(F)ANEVH1500-80 LC(F)
Input
Phase
Three-phase three-wire +PE
Voltage
340V~480Vac
Frequency50/60Hz
Power Factor≥ 0.99 (typical value)
Output
Voltage0 - 500V DC
0 - 1500V DC
Current-240A - 240A
-80A - 80A
Power-40kW - 40kW
-40kW - 40kW
Display Mode
8.8-inch color touchscreen
Voltage Resolution
0.001V
Current Resolution
0.001A
Power Resolution
0.001kW

Setting Error

(Programming Accuracy) *

Voltage
≤0.02%F.S.
Current≤0.05%F.S.
Power≤0.2%FS

Measurement Error

(Read-back Accuracy) *

Voltage≤0.02%F.S.
Current≤0.05%F.S.
Power≤0.2%FS

Ripple and Noise

 20Hz - 20MHz

Vrms≤85mVrms≤170mVrms
Vpp≤800mVpp≤2200mVpp
Load EffectVoltage≤0.015%Umax
Current≤0.05%Imax
Source Effect
Voltage≤0.02%Umax
Current≤0.02%Imax
Voltage Slew Rate *100V/ms500V/ms
Transient Response Time *
≤2ms
Forward and Reverse Switching Speed2ms(+90%→-90%)
Temperature Drift
Voltage
100ppm/℃
Current100ppm/℃
OVP Range
110%F.S
Maximum Lead Voltage Drop Compensation≤5% Umax
Communication FunctionsCAN/RS-232/485/LAN/USB (standard) (optional) GPIB
Protection FunctionsInput undervoltage protection, short-circuit protection, output overvoltage/current-limiting protection, and internal overheating protection.
Analog Interface (Optional)Startup, stop, alarm, 0-5V or 0-10V analog control output
Other External InterfacesStandard: Parallel Operation Port, Interlock Port
Efficiency≤94%
Feedback ParametersFrequency45-66HZ
Power Factor≥0.99 (typical value)
Total Harmonic Content≤5%(typical value, power grid simulator input with distortion less than 1.5%)
Feedback FunctionFull power range feedback
Feedback Efficiency≤94%

Insulation and Voltage Resistance

DC Negative Terminal to Ground±1500V DC
DC Positive Terminal to Ground
+1800V DC
AC Input <->PE2.5kV DC
Operating Temperature0 - 50℃
Inlet water Temperature (max.)+26℃
Inlet water Temperature (min.)
See dew-point table
Flow RateMin. 7L/min
Water PressureMin. 1bar, Max. 4bar
Storage Temperature-20℃ - 70℃
Humidity
<80%, without condensation
DimensionsEnclosure Size(W*H*D mm)482*177*705.5mm
Overall Dimensions(W*H*D mm)482*177*808.5mm
Weight≤ 60kg
Remarks

*1 & *2. Programming accuracy/read-back accuracy test condition (25℃±5℃);

*3. Voltage rise time from 10% to 90% of ΔUout under no-load conditions

*4. Time required for the load to change from 100% to 50% or in reverse, and for the output voltage to return to within "rated value±0.75%", with output voltage ≥30% Umax

* Any changes to the above parameter specifications will not be notified separately.

Additional ANEVH LC 40kW Water-Cooled Models. For customization, please talk to us.