ANPA4000(F) Multi-Channel High Precision Power Analyzer - Ainuo Instrument
Home   >   Products>Measuring Instruments>Power Analyzer>Power Analyzer>ANPA4000(F) Multi-Channel High-Precision Power Analyzer

ANPA4000(F) Multi-Channel High Precision Power Analyzer

Specifications:
Accuracy: 0.03%
Sampling Rate: 2MS/s
Max V/C: 1000V/30A
Height: 4U
Applications:
Suitable for testing equipment such as photovoltaic inverters, electric vehicles, OBCs, charging piles, motor test benches, variable frequency motors, switching power supplies, power electronics, and transformers.
Product overview Product features Product application Technical specifications
Product overview

Download Latest Product Catalog

ANPA4000(F) Series is a multi-channel, high-precision power analyzer that supports simultaneous measurement on 1 to 8 channels and can be flexibly configured for single-phase, three-phase, and other modes.

It features FPGA+ARM dual-core processing with 16‑bit high‑speed AD converters, achieving a basic accuracy of 0.03% of reading + 0.05% of range.

The instrument offers a wide frequency band (DC, 0.5 Hz to 1 MHz), multi‑channel harmonic analysis (up to the 500th order), motor measurement, efficiency calculation, energy accumulation, and other comprehensive functions. Standard current input is 30 A, with optional 5 A and external sensor inputs available.

It provides a full touchscreen experience and supports custom data storage and export. The series is widely used in photovoltaic inverters, electric vehicles, charging stations, motor test benches, and switching power supplies.

Product features
  • Eight-channel synchronous power analysis;

  • Basic accuracy: 0.03%×Reading+0.05%×Range;

  • Sampling Rate: 2MS/s;

  • Maximum voltage: 1000V (DC1500V);

  • Rich specifications: 30A (standard) /5A (optional), standard BNC interface, and optional sensors;

  • Motor test: optional motor test channel;

  • LCD: full touch screen experience, customizable display interface items, and multiple waveform displays;

  • Data storage: customizable storage items, CSV format export, and on-device screenshot saving;

  • Perfect size: standard 4U height, compliant with system integration requirements.

Product application

Channel Configuration of Power Analyzer ANPA4000(F)

Motor Bench and Variable Frequency Motor Measurement

  • Complying with GB/T 18488-2024 Drive Motor Systems for Electric Vehicles;

  • Capable of simultaneously measuring up to four motors, supporting 500 harmonic measurements and distortion analysis;

  • Supporting pulse-type and analog-type speed/torque sensors (optional);

  • Torque, speed, mechanical power, efficiency, and electrical phase angle measurement functions (optional).

Motor Bench and Variable Frequency Motor Measurement

Electric vehicle electrical performance measurement

  • Up to 8 channels for simultaneous measurement, capable of simultaneously detecting multiple parameters;

  • Supports OBC, charging pile efficiency tests, battery charge and discharge performance, power conversion performance, motor performance, etc;

  • Supports high voltage and current measurement, with a maximum voltage of 1000V (DC 1500V) and a maximum current of 30A. Larger current sensors can be extended for application;

  • Basic accuracy: 0.03%×Reading+0.05%×Range; minimum power resolution 0.1 mW;

  • Capable of measuring signal ripple rate, three-phase unbalance rate, power factor, fundamental reactive power, and other parameters.

EV Electrical Performance Measurement

Photovoltaic inverter power measurement

  • Comply with the testing specification for Photovoltaic Grid-connected Inverter Standard GB/T 37409-2019;

  • Compliant with《GB/T 34133-2023 Technical Code for Testing of Energy Storage Converters》;

  • Supports high voltage and current measurement, with a maximum voltage of 1000V (DC 1500V) and a maximum current of 30A;

  • Larger current sensors can be extended for application;

  • Harmonic measurement and flicker measurement based on IEC standards;

  • Analysis of up to 500 times harmonics and distortion;

  • Bidirectional power measurement for buying and selling electricity.

PV Inverter Power Measurement

Various power supply and UPS power measurement

  • Current range of 0-30A/5A;

  • Power bandwidth DC, 0.5Hz-1MHz;

  • Simultaneously measures input and output (single-phase and three-phase) power, and monitors battery charge and discharge;

  • Automatic efficiency calculation.

Various Power Supply and UPS Power Measurement

Technical specifications
Product ModelANPA4000(F)
Current Specifications30A (5 A optional) 
Wiring Method

1P3W (single-phase 3-wire), 3P3W (3-phase 3-wire, 2 voltage 2 current)

3V3A (3-phase 3-wire, 3 voltage 3 current), 3P4W (3-phase 4-wire)

Sampling Rate2MS/s
Full Range Peak Factor3 or 6 
Voltage Rated Range (Direct Input)15/30/60/100/150/300/600/1000*[V](peak factor 3)
7.5/15/30/50/75/150/300/500*[V] (peak factor 6)
*1,000V full range peak factor is 1.5
Current Rated Range (Direct Input)30A:1/2/5/10/20/30*[A](peak   factor 3)
5A:100m/200m/500m/1/2/5*[A](peak factor 3)
30A:500m/1/2.5/5/10/15*[A](peak factor 6)
5: 50m/100m/250m/0.5/1/2.5*[A](peak factor 6)
Current Rated Range (Sensor Input)200m/500m/1/2/5/10[V]   (peak factor 3)
100m/250m/500m/1/2.5/5[V] (peak factor 6)
Voltage/Current Measurement Range(1%-110%)*Range
Power Factor Range±(0,0001  - 1,0000)
Current Measurement AccuracyDC±(0.05% * Reading + 0.05% * Range)
0.1Hz≤f<45Hz±[(0.03% * Reading + 0.05% * Range)+ (2μA*)]
45Hz≤f≤66Hz±[(0.03% * Reading + 0.05% * Range)+ (2μA*)]
66Hz<f≤1kHz±(0.1% * Reading + 0.1% * Range)
1kHz<f≤50kHz±(0.3% * Reading + 0.1% * Range)
50kHz<f≤100kHz±(0.6% * Reading + 0.2% * Range)
100kHz < f ≤ 500kHz±[(0.006 × f )% * Reading + 0.5% * Range]
500kHz < f ≤ 1MHz±[(0.022 × f - 8)% * Reading + 1% * Range]
Active Power Measurement AccuracyDC±(0.05% * Reading + 0.05% * Range)
0.1Hz≤f<45Hz±(0.08% * Indicating value + 0.1% * Range)
45Hz≤f≤66Hz±(0.05% * Reading + 0.05% * Range)
66Hz<f≤1kHz±(0.2% * Indicating value + 0.1% * Range)
1kHz<f≤50kHz±(0.3% * Indicating value + 0.2% * Range)
50kHz<f≤100kHz±(0.7% * Indicating value + 0.3% * Range)
100kHz < f ≤ 500kHz±[(0.02 × f )% * Reading + 1% * Range]
500kHz < f ≤ 1MHz±[(0.04 × f )% * Reading + 3% * Range]
TypePower Card
Active Power Measurement range00.02W-6.6kW/phase @ 220V, PF=0.01-1 (30A board card)
Highest Resolution of Active Power30A: 1mW; 5A: 0.1mW
Frequency Measurement RangeDC, 0.1Hz - 1MHz
Frequency Measurement Accuracy±0.06%×Indicating value
Harmonic Measurement10Hz - 2.6kHz, maximum 500th harmonic content, total distortion
Energy Measurement Range0-99999MWh (resolution: 1mWh/0.01mAh)
Energy Measurement Accuracy±0.2%×Indicating value
Energy Measurement Timing9999 hours 59 minutes 59 seconds
Filter Function

Frequency filtering optional: 500 Hz, 10 kHz, 100 kHz, 1MHz;

Line filtering optional: 100-10 kHz (step 100 Hz), 50kHz, 100 kHz.

Voltage and Current Ratio Range1.00-50000.00
External Input Ratio0.10-100.00
Data Update Cycle10m/20m/50m/100m/200m/500m/1/2/5/10/20[s]
Control InterfaceTest cycle synchronization interface (compatible with trigger lock function), standard configuration: RS-232, LAN; optional: RS-485
Communication Protocol MODBUSTCP MODBUSSCPI
Overall Dimensions (W*H*D mm)426 * 175 * 462
Opening Size (W*H*D mm)426 * 175
Foot Height17.5mm
WeightApproximately 20kg
Whole Unit Power Consumption66W


TypeMotor Card
Input InterfaceInsulated BNC
Input ResistanceApproximately 1MΩ
Input ChannelSingle Motor (Speed: Pulse)
ChA(Torque)Analog/Pulse Input
ChB(SpeedA)Pulse A-phase (Rotational Speed)
ChC(SpeedB)Pulse B-phase (Rotation Direction)
ChD(SpeedZ)Pulse Z Phase (Electrical Angle Reference)
Single Motor (Speed: Analog)
ChA (Torque)Analog/Pulse Input
ChB ()
ChC (Speed)Analog/Pulse Input
ChD ()
Dual Motors
ChA (Torque)Analog/Pulse Input
ChB (Speed)Pulse Input
ChC (Torque)Analog/Pulse Input
ChD (Speed)Pulse Input
Input TypeAnalog Input
Rated Range1/2/5/10/20*[V]
Measurement Range(1%-110%) * range
Maximum Permissible Input22V
Sampling RateApproximately 200KS/s
Measurement Accuracy±(0.05% * indicating value + 0.05% * range)
Pulse Input
Rated Range10V
Amplitude Range±12Vpeak
Detection Level - H Level≥2V
Detection Level - L Level≤0.8V
Pulse Width≥500ns
Frequency Range2Hz-1MHz
Measurement Accuracy±(0.05% * indicating value + 0.001Hz)